Your browser doesn't support javascript.
loading
Measurements of occupational exposure for a technologist performing 18F FDG PET scans.
Biran, Talma; Weininger, Jolie; Malchi, Shalom; Marciano, Rami; Chisin, Roland.
Afiliação
  • Biran T; Radiation Safety Division, Soreq NRC, Yavne, Israel. talma@soreq.gov.il
Health Phys ; 87(5): 539-44, 2004 Nov.
Article em En | MEDLINE | ID: mdl-15551792
Radiation doses to one PET technologist performing 100 18F FDG (18F fluorodeoxyglucose) imaging procedures were measured in a clinical setting using two types of thermoluminescent dosimeter (TLD) badges, one finger-ring TLD and one electronic pocket dosimeter (EPD). 18F FDG was handled either with unshielded or with viewing window tungsten shielded syringes. The resulting doses using unshielded syringes were 13.8 +/- 0.8 microSv/370 MBq and 14.3 +/- 0.4 microSv/370 MBq, measured with TLD 100 and with TLD 700H/600H, respectively. For the same series of measurements, the doses obtained using shielded syringes were 10.7 +/- 0.4 microSv/370 MBq and 7.2 +/- 2.1 microSv/370 MBq with TLD700H/600H and with EPD, respectively. The dose to the right hand from shielded syringes was 69.3 +/- 5.5 microSv/370 MBq. All these values are within the ICRP recommended dose limits. Extrapolated to 725 examinations per year, the resulting effective dose measured with TLD would be 10 mSv with unshielded and 7.5 mSv with shielded syringes, respectively (25% dose reduction). The doses measured by TLD were consistently higher than those measured by EPD, suggesting that EPD measurements might underestimate occupational doses.
Assuntos
Buscar no Google
Bases de dados: MEDLINE Assunto principal: Proteção Radiológica / Dosimetria Termoluminescente / Exposição Ocupacional / Pessoal de Laboratório Médico / Medição de Risco / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Risk_factors_studies Limite: Adult / Humans / Male Idioma: En Revista: Health Phys Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Israel
Buscar no Google
Bases de dados: MEDLINE Assunto principal: Proteção Radiológica / Dosimetria Termoluminescente / Exposição Ocupacional / Pessoal de Laboratório Médico / Medição de Risco / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Risk_factors_studies Limite: Adult / Humans / Male Idioma: En Revista: Health Phys Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Israel