Your browser doesn't support javascript.
loading
Diagnostic ionizing radiation exposure in a population-based cohort of patients with inflammatory bowel disease.
Peloquin, Joanna M; Pardi, Darrell S; Sandborn, William J; Fletcher, Joel G; McCollough, Cynthia H; Schueler, Beth A; Kofler, James A; Enders, Felicity T B; Achenbach, Sara J; Loftus, Edward V.
Afiliação
  • Peloquin JM; Department of Medicine, Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Mayo Clinic, Rochester, Minnesota 55905, USA.
Am J Gastroenterol ; 103(8): 2015-22, 2008 Aug.
Article em En | MEDLINE | ID: mdl-18564113
OBJECTIVE: For diagnosis, assessing disease activity, complications and extraintestinal manifestations, and monitoring response to therapy, patients with inflammatory bowel disease undergo many radiological studies employing ionizing radiation. However, the extent of radiation exposure in these patients is unknown. METHODS: A population-based inception cohort of 215 patients with inflammatory bowel disease from Olmsted County, Minnesota, diagnosed between 1990 and 2001, was identified. The total effective dose of diagnostic ionizing radiation was estimated for each patient. Linear regression was used to assess the median total effective dose since symptom onset. RESULTS: The number of patients with Crohn's disease and ulcerative colitis was 103 and 112, with a mean age at diagnosis of 38.6 and 39.4 yr, respectively. Mean follow-up was 8.9 yr for Crohn's disease and 9.0 yr for ulcerative colitis. Median total effective dose for Crohn's disease was 26.6 millisieverts (mSv) (range, 0-279) versus 10.5 mSv (range, 0-251) for ulcerative colitis (P < 0.001). Computed tomography accounted for 51% and 40% of total effective dose, respectively. Patients with Crohn's disease had 2.46 times higher total effective dose than ulcerative colitis patients (P= 0.001), adjusting for duration of disease. CONCLUSIONS: Annualizing our data, the radiation exposure in the inflammatory bowel disease population was equivalent to the average annual background radiation dose from naturally occurring sources in the U.S. (3.0 mSv). However, a subset of patients had substantially higher doses. The development of imaging management guidelines to minimize radiation dose, dose-reduction techniques in computed tomography, and faster, more robust magnetic resonance techniques are warranted.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Doses de Radiação / Colite Ulcerativa / Doença de Crohn Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Am J Gastroenterol Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Doses de Radiação / Colite Ulcerativa / Doença de Crohn Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Am J Gastroenterol Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos