Your browser doesn't support javascript.
loading
Role of three-dimensional power Doppler in the antenatal diagnosis of placenta accreta: comparison with gray-scale and color Doppler techniques.
Shih, J C; Palacios Jaraquemada, J M Palacios; Su, Y N; Shyu, M K; Lin, C H; Lin, S Y; Lee, C N.
Afiliação
  • Shih JC; Department of Obstetrics and Gynecology, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan.
Ultrasound Obstet Gynecol ; 33(2): 193-203, 2009 Feb.
Article em En | MEDLINE | ID: mdl-19173239
ABSTRACT

OBJECTIVE:

To assess the role of three-dimensional (3D) power Doppler in the antenatal diagnosis of placenta accreta and compare its diagnostic performance with gray-scale and color Doppler ultrasonography.

METHODS:

One hundred and seventy pregnant women with persistent placenta previa totalis (after 28 weeks' gestation) were prospectively enrolled into this study. Gray-scale transabdominal ultrasound examination was performed to detect loss of the subendometrial echolucent zone and other abnormalities suggestive of placenta accreta. Color flow mapping was used to scan the whole placenta to detect any newly formed vessels at the serosa-bladder border or the presence of abnormal lacunae. Finally a targeted examination of angioarchitecture in the basal and lateral views of the placenta was carried out using 3D power Doppler. The ultrasound findings were analyzed with reference to the final diagnosis made during Cesarean delivery.

RESULTS:

Placenta accreta and its variants (including increta and percreta) were confirmed in 39 patients at the time of Cesarean delivery. Based on receiver-operating characteristics analysis, 'numerous coherent vessels' visualized using 3D power Doppler in the basal view was the best single criterion for the diagnosis of placenta accreta, with a sensitivity of 97% and a specificity of 92%. If we considered the presence of at least one criterion to be diagnostic when using each ultrasound technique, then 3D power Doppler would have the best positive predictive value (76%), followed by gray-scale (51%) and color Doppler (47%). The majority of patients with placenta accreta showed multiple characteristic features on ultrasound imaging. In contrast, those patients with a false-positive diagnosis (i.e. the final diagnosis was placenta previa alone) tended to show isolated ultrasound markers of the condition.

CONCLUSION:

3D power Doppler may be useful as a complementary technique for the antenatal diagnosis or exclusion of placenta accreta.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Placenta Acreta / Ultrassonografia Pré-Natal / Ultrassonografia Doppler Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Ultrasound Obstet Gynecol Assunto da revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Placenta Acreta / Ultrassonografia Pré-Natal / Ultrassonografia Doppler Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Ultrasound Obstet Gynecol Assunto da revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Taiwan