Your browser doesn't support javascript.
loading
Left ventricular dyssynchrony assessment by phase analysis from gated PET-FDG scans.
Pazhenkottil, Aju P; Buechel, Ronny R; Nkoulou, Rene; Ghadri, Jelena-Rima; Herzog, Bernhard A; Husmann, Lars; Wolfrum, Mathias; Küest, Silke M; Fiechter, Michael; Gaemperli, Oliver; Kaufmann, Philipp A.
Afiliação
  • Pazhenkottil AP; Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
J Nucl Cardiol ; 18(5): 920-5, 2011 Oct.
Article em En | MEDLINE | ID: mdl-21671145
BACKGROUND: The outcome of patients with severe ischaemic left ventricular (LV) dysfunction is determined by the extent of myocardial viability and the presence of LV dyssynchrony. We aimed at assessing both parameters from the same imaging method, i.e. gated positron emission tomography (PET) F18-fluorodeoxyglucose (FDG) scans. METHODS: Phase analysis from Emory Cardiac Toolbox was applied on gated PET-FDG scans to assess histogram bandwidth and standard deviation (SD) as a measure of LV dyssynchrony in 30 heart failure patients (mean ejection fraction: 30.2% ± 13.8%) referred for the evaluation of myocardial viability. Cut-off values from single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) best predicting cardiac resynchronization therapy (CRT) response served as standard of reference (bandwidth < 135°; phase SD < 43°). Severe LV dyssynchrony was diagnosed if both SPECT-MPI values were above these limits. Intraclass correlation and clinical agreement in detection of severe LV dyssynchrony by PET vs SPECT were assessed. RESULTS: There was a significant correlation between PET-FDG and SPECT-MPI for bandwidth (r = 0.88, P < .001) and phase SD (r = 0.88, P < .001) resulting in an excellent clinical agreement between the two methods of 93%. CONCLUSIONS: Accurate LV dyssynchrony assessment by phase analysis of gated PET-FDG scans is feasible, allowing assessing myocardial viability and severe LV dyssynchrony in one scan.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Imagem de Perfusão do Miocárdio Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Imagem de Perfusão do Miocárdio Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Suíça