Your browser doesn't support javascript.
loading
Predictors of pacemaker dependence and pacemaker dependence as a predictor of mortality in patients with implantable cardioverter defibrillator.
Sood, Nitesh; Crespo, Eric; Friedman, Meir; Guertin, Danette; Zweibel, Steven; Kluger, Jeffrey; Clyne, Christopher A.
Afiliação
  • Sood N; Division of Cardiology, Lahey Clinic, Burlington, Massachusetts, USA.
Pacing Clin Electrophysiol ; 36(8): 945-51, 2013 Aug.
Article em En | MEDLINE | ID: mdl-23668483
BACKGROUND: The prevalence, predictors, and survival for the development of pacemaker dependence (PD) in patients implanted with an implantable cardioverter defibrillator (ICD) are unknown. METHODS: This was a retrospective analysis of 1,550 consecutive patients with ICD implantation at a single center from 1996 to 2008 with a mean of 4.2 ± 3.4 years. Patients with implant intrinsic heart rates less than 40 beats/min (n = 48) and cardiac resynchronization therapy (n = 444) were excluded leaving 1,058 patients in this study. PD was defined as an intrinsic rhythm <40 beats/min after inhibiting the pacemaker, <50 beats/min with transient symptoms of dizziness relieved by resumption of pacing and right ventricle pacing despite algorithms to promote intrinsic conduction at the 3 monthly follow-up ICD clinic visits. Multivariate regression and Cox proportional hazard models were used for analysis. RESULTS: The mean age was 64 ± 13 years; 79% were male with a primary indication for the ICD in 57%. PD occurred in 142 (13.4%) of patients, with a mean time to PD of 2.6 ± 1.9 years. PD was associated with a 48% increased odds for mortality versus non-PD ICD patients during the mean follow-up time of 4.2 ± 3.4 years (adjusted odds ratio = 1.48 [95% confidence interval 1.080-2.042]; P = 0.015). Older age, a history of atrial fibrillation, amiodarone use, and secondary prevention were the strongest predictors for the development of PD. CONCLUSIONS: In this single-center ICD cohort, the development of PD was not uncommon and was associated with decreased survival.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Arritmias Cardíacas / Cardioversão Elétrica / Estimulação Cardíaca Artificial / Desfibriladores Implantáveis Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Arritmias Cardíacas / Cardioversão Elétrica / Estimulação Cardíaca Artificial / Desfibriladores Implantáveis Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos