Your browser doesn't support javascript.
loading
The use of Bowman's layer vertical topographic thickness map in the diagnosis of keratoconus.
Abou Shousha, Mohamed; Perez, Victor L; Fraga Santini Canto, Ana Paula; Vaddavalli, Pravin K; Sayyad, Fouad E; Cabot, Florence; Feuer, William J; Wang, Jianhua; Yoo, Sonia H.
Afiliação
  • Abou Shousha M; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida; Saint Louis University Eye Institute, Saint Louis University, St. Louis, Missouri; Department of Ophthalmology, Faculty of Medicine, University of Alexandria, Alexandria, Egypt.
  • Perez VL; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida.
  • Fraga Santini Canto AP; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida.
  • Vaddavalli PK; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida.
  • Sayyad FE; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida.
  • Cabot F; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida.
  • Feuer WJ; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida.
  • Wang J; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida.
  • Yoo SH; Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida. Electronic address: syoo@med.miami.edu.
Ophthalmology ; 121(5): 988-93, 2014 May.
Article em En | MEDLINE | ID: mdl-24468653
PURPOSE: To evaluate the use of Bowman's layer (BL) vertical topographic thickness maps in diagnosing keratoconus (KC). DESIGN: Prospective, case control, interventional case series. PARTICIPANTS: A total of 42 eyes: 22 eyes of 15 normal subjects and 20 eyes of 15 patients with KC. INTERVENTION: Bowman's layer 2-dimensional 9-mm vertical topographic thickness maps were created using custom-made ultra high-resolution optical coherence tomography. MAIN OUTCOME MEASURES: Bowman's layer average and minimum thicknesses of the inferior half of the cornea, Bowman's ectasia index (BEI; defined as BL minimum thickness of the inferior half of the cornea divided by BL average thickness of the superior half of the cornea multiplied by 100), BEI-Max (defined as BL minimum thickness of the inferior half of the cornea divided by BL maximum thickness of the superior half of the cornea multiplied by 100), keratometric astigmatism (Ast-K) of patients with KC, and average keratometric (Avg-K) readings. RESULTS: In patients with KC, BL vertical thickness maps disclosed localized relative inferior thinning of the BL. Inferior BL average thickness (normal = 15±2, KC = 12±3 µm), inferior BL minimum thickness (normal = 13±2, KC = 7±3 µm), BEI (normal = 91±7, KC = 48±14), and BEI-Max (normal = 75±8; KC = 40±13) all showed highly significant differences in KC compared with normal subjects (P< 0.001). Receiver operating characteristic (ROC) curve analysis showed excellent predictive accuracy for BEI and BEI-Max with 100% sensitivity and specificity (area under the curve [AUC] of 1) with cutoff values of 80 and 60, respectively. The AUC of inferior BL average thickness and minimum thickness were 0.87 and 0.96 with a sensitivity of 80% and 93%, respectively, and a specificity of 93% and 93%, respectively. Inferior BL average thickness, inferior BL minimum thickness, BEI, and BEI-Max correlated highly to Ast-K (R = -0.72, -0.82, -0.84, and -0.82, respectively; P< 0.001) and to Avg-K (R = -0.62, P< 0.001; R = -0.59, P = 0.001; R = -0.60, P< 0.001; and R = -0.59, P = 0.001, respectively). CONCLUSIONS: Bowman's layer vertical topographic thickness maps of patients with KC disclose characteristic localized relative inferior thinning. Inferior BL average thickness, inferior BL minimum thickness, BEI, and BEI-Max are qualitative and quantitative indices for the diagnosis of KC that accurately correlate with the severity of KC. In our pilot study, BEI and BEI-Max showed excellent accuracy, sensitivity, and specificity in the diagnosis of KC.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Topografia da Córnea / Lâmina Limitante Anterior / Ceratocone Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Ophthalmology Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Topografia da Córnea / Lâmina Limitante Anterior / Ceratocone Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Ophthalmology Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Egito