Non-invasive cardiac output evaluation in postoperative cardiac surgery patients, using a new prolonged expiration-based technique.
Mattei, Alessia; Schena, Emiliano; Cecchini, Stefano; Proscia, Paola; Saccomandi, Paola; Silvestri, Sergio; Carassiti, Massimiliano.
Afiliação
  • Mattei A; Department of Anaesthesia, University School of Medicine Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Rome, Italy.
J Clin Monit Comput ; 28(6): 625-32, 2014 Dec.
Article em En | MEDLINE | ID: mdl-24562985
The gold standard methods to measure cardiac output (CO) are invasive and expose the patient to high risks of various complications. The aim of this study is to assess an innovative non-invasive method for CO monitoring in mechanically ventilated patients after cardiac surgery and its agreement with values obtained by thermodilution technique. Continuous monitoring of respiratory gas concentrations and airflow allows the estimation of CO through a newly developed algorithm derived from a modified version of the Fick equation. It consists of two phases: the first involves measurements during steady breathing state, and the second starts when a sudden perturbation into the carbon dioxide elimination process is introduced by a prolonged expiration. This prospective clinical study involved thirty-five adult patients, undergone cardiac surgery. The measurements were performed in curarized and haemodynamically stable patients, during the post-surgery recovery in intensive care unit. The study protocol, which lasted 1 h for each patient, consisted of 20 measurements obtained by prolonged expiration-based method and 10 by thermodilution. The estimation of CO using the proposed method (COK) agreed with the thermodilution (COT) as demonstrated by: a low mean bias between COK and COT considering all patients (i.e., -0.11 L min(-1)); a best fitting line having slope = 0.98, r = 0.81, p < 0.0001; the lower and upper limits of agreement were -0.77 and +0.54 L min(-1), respectively. COK shows a mean percentage error of 34 %. In stable mechanically ventilated patients, undergone cardiac surgery, the proposed method is reliable if compared to the thermodilution. Considering the non-invasivity of the technique, further evaluations of its performances are encouraged.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Cuidados Pós-Operatórios / Respiração Artificial / Testes Respiratórios / Débito Cardíaco / Troca Gasosa Pulmonar / Monitorização Intraoperatória / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Diagnostic_studies / Guideline Limite: Aged / Female / Humans / Male Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Cuidados Pós-Operatórios / Respiração Artificial / Testes Respiratórios / Débito Cardíaco / Troca Gasosa Pulmonar / Monitorização Intraoperatória / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Diagnostic_studies / Guideline Limite: Aged / Female / Humans / Male Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Itália