Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD: a substudy of the ECOST trial.
Guédon-Moreau, Laurence; Kouakam, Claude; Klug, Didier; Marquié, Christelle; Brigadeau, François; Boulé, Stéphane; Blangy, Hugues; Lacroix, Dominique; Clémenty, Jacques; Sadoul, Nicolas; Kacet, Salem.
Afiliação
  • Guédon-Moreau L; Centre Hospitalier Régional Universitaire, Hôpital Cardiologique, Lille, France.
J Cardiovasc Electrophysiol ; 25(7): 763-70, 2014 Jul.
Article em En | MEDLINE | ID: mdl-24602062
INTRODUCTION: Inappropriate shocks remain a highly challenging complication of implantable cardioverter defibrillators (ICD). We examined whether automatic wireless remote monitoring (RM) of ICD, by providing early notifications of triggering events, lowers the incidence of inappropriate shocks. METHODS AND RESULTS: We studied 433 patients randomly assigned to RM (n = 221; active group) versus ambulatory follow-up (n = 212; control group). Patients in the active group were seen in the ambulatory department once a year, unless RM reported an event requiring an earlier ambulatory visit. Patients in the control group were seen in the ambulatory department every 6 months. The occurrence of first and further inappropriate shocks, and their causes in each group were compared. The characteristics of the study groups, including pharmaceutical regimens, were similar. Over a follow-up of 27 months, 5.0% of patients in the active group received ≥1 inappropriate shocks versus 10.4% in the control group (P = 0.03). A total of 28 inappropriate shocks were delivered in the active versus 283 in the control group. Shocks were triggered by supraventricular tachyarrhythmias (SVTA) in 48.5%, noise oversensing in 21.2%, T wave oversensing in 15.2%, and lead dysfunction in 15.2% of patients. The numbers of inappropriate shocks delivered per patient, triggered by SVTA and by lead dysfunction, were 74% and 98% lower, respectively, in the active than in the control group. CONCLUSION: RM was highly effective in the long-term prevention of inappropriate ICD shocks.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Falha de Prótese / Cardioversão Elétrica / Telemedicina / Desfibriladores Implantáveis / Traumatismos por Eletricidade / Tecnologia de Sensoriamento Remoto Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Falha de Prótese / Cardioversão Elétrica / Telemedicina / Desfibriladores Implantáveis / Traumatismos por Eletricidade / Tecnologia de Sensoriamento Remoto Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França