Your browser doesn't support javascript.
loading
Analysis of automatic match results for cone-beam computed tomography localization of conventionally fractionated lung tumors.
Grams, Michael P; Brown, Lindsay C; Brinkmann, Debra H; Pafundi, Deanna H; Mundy, Daniel W; Garces, Yolanda I; Park, Sean S; Olivier, Kenneth R; de los Santos, Luis E Fong.
Afiliação
  • Grams MP; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • Brown LC; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • Brinkmann DH; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • Pafundi DH; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • Mundy DW; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • Garces YI; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • Park SS; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • Olivier KR; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota.
  • de los Santos LE; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota. Electronic address: fongdelossantos.luis@mayo.edu.
Pract Radiat Oncol ; 4(1): 35-42, 2014.
Article em En | MEDLINE | ID: mdl-24621421
ABSTRACT

PURPOSE:

To evaluate the dependence of an automatic match process on the size of the user-defined region of interest (ROI), the structure volume of interest (VOI), and changes in tumor volume when using cone-beam computed tomography (CBCT) for tumor localization and to compare these results with a gold standard defined by a physician's manual match. METHODS AND MATERIALS Daily CBCT images for 11 patients with lung cancer treated with conventionally fractionated radiation therapy were retrospectively matched to a reference CT image using the Varian On Board Imager software (Varian, Palo Alto, CA) and a 3-step automatic matching protocol. Matches were performed with 3 ROI sizes (small, medium, large), with and without a structure VOI (internal target volume [ITV] or planning target volume [PTV]) used in the last step. Additionally, matches were performed using an intensity range that isolated the bony anatomy of the spinal column. All automatic matches were compared with a manual match made by a physician.

RESULTS:

The CBCT images from 109 fractions were analyzed. Automatic match results depend on ROI size and the structure VOI. Compared with the physician's manual match, automatic matches using the PTV as the structure VOI and a small ROI resulted in differences ≥ 5 mm in 1.8% of comparisons. Automatic matches using no VOI and a large ROI differed by ≥ 5 mm in 30.3% of comparisons. Differences between manual and automatic matches using the ITV as the structure VOI increased as tumor size decreased during the treatment course.

CONCLUSIONS:

Users of automatic matching techniques should carefully consider how user-defined parameters affect tumor localization. Automatic matches using the PTV as the structure VOI and a small ROI were most consistent with a physician's manual match, and were independent of volumetric tumor changes.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Tomografia Computadorizada de Feixe Cônico / Neoplasias Pulmonares Tipo de estudo: Guideline / Observational_studies Limite: Female / Humans / Male Idioma: En Revista: Pract Radiat Oncol Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Tomografia Computadorizada de Feixe Cônico / Neoplasias Pulmonares Tipo de estudo: Guideline / Observational_studies Limite: Female / Humans / Male Idioma: En Revista: Pract Radiat Oncol Ano de publicação: 2014 Tipo de documento: Article