Your browser doesn't support javascript.
loading
Results of first proficiency test for KRAS testing with formalin-fixed, paraffin-embedded cell lines in China.
Clin Chem Lab Med ; 52(12): 1851-7, 2014 Dec.
Article em En | MEDLINE | ID: mdl-24945428
BACKGROUND: Laboratory testing for KRAS (v-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog) mutations in metastatic colorectal cancer (mCRC) is performed by various methods in China, but there is no standardized system for proficiency testing or assay performance evaluations. The aim of this study was to evaluate assay and laboratory performance with artificial samples derived from formalin-fixed, paraffin-embedded (FFPE) cell lines. METHODS: Artificial FFPE samples were prepared from cultured cell lines to construct a proficiency panel of 10 samples covering eight KRAS mutations and two wild-type samples. The samples were validated by Sanger sequencing and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The panel was distributed to participating laboratories and their reported results were compared to the reference sequences. RESULTS: The percentages of mutant KRAS alleles in each mutant sample were more than 50% by MALDI-TOF-MS. Sixty-three laboratories reported results, including 41 hospital laboratories and 22 commercial laboratories and reagent manufacturers. Only 55.6% (35/63) of the laboratories correctly identified the mutations in all samples and 33.3% (21/63) reported at least one false-positive result. The false-positive ratio was 7.1% (45/630) and the false-negative ratio was 3.0% (15/504). CONCLUSIONS: KRAS mutations can be missed even by the most sensitive methods if the procedures are not performed correctly. False-positive results are a substantial problem in KRAS testing; laboratories must use sufficient negative controls to identify cross-contamination from PCR-amplified products or between samples during handling and DNA extraction.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Análise Mutacional de DNA / Proteínas ras / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz Tipo de estudo: Prognostic_studies Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Análise Mutacional de DNA / Proteínas ras / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz Tipo de estudo: Prognostic_studies Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2014 Tipo de documento: Article