Your browser doesn't support javascript.
loading
Real-time stability testing of air-dried primers and fluorogenic hydrolysis probes stabilized by trehalose and xanthan.
Rombach, Markus; Kosse, Dominique; Faltin, Bernd; Wadle, Simon; Roth, Günter; Zengerle, Roland; von Stetten, Felix.
Afiliação
  • Rombach M; HSG-IMIT-Institut für Mikro- und Informationstechnik, Freiburg, Germany; Laboratory for MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.
  • Kosse D; HSG-IMIT-Institut für Mikro- und Informationstechnik, Freiburg, Germany.
  • Faltin B; Laboratory for MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.
  • Wadle S; BIOSS Centre for Biological Signalling Studies, University of Freiburg, Freiburg, Germany.
  • Roth G; HSG-IMIT-Institut für Mikro- und Informationstechnik, Freiburg, Germany; Laboratory for MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany; BIOSS Centre for Biological Signalling Studies, University of Freiburg, Freiburg, Germany.
  • Zengerle R; HSG-IMIT-Institut für Mikro- und Informationstechnik, Freiburg, Germany; Laboratory for MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany; BIOSS Centre for Biological Signalling Studies, University of Freiburg, Freiburg, Germany.
  • von Stetten F; HSG-IMIT-Institut für Mikro- und Informationstechnik, Freiburg, Germany; Laboratory for MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.
Biotechniques ; 57(3): 151-5, 2014.
Article em En | MEDLINE | ID: mdl-25209050
A method for conserving primers and differently labeled fluorogenic hydrolysis (i.e., TaqMan) probes at ambient conditions is presented. Primers and hydrolysis probes with four different fluorophore-quencher combinations (6- FAM-BHQ1, HEX-BHQ1, ROX-BHQ650, and Cy5-BHQ2) were mixed with trehalose and xanthan at final concentrations of 56 mM and 2.78 mM, respectively. Mixtures were air-dried at 23°C for 30 min on strips composed of cyclo olefin polymer (COP), a material widely used in the manufacturing of in vitro diagnostic (IVD) test carriers. After one year of storage, the functionality of the primers and fluorophore-quencher combinations was validated by real-time polymerase chain reaction (real-time PCR), confirming their stability when stored in the presence of stabilizers, with the best results achieved using trehalose. This approach could be of great benefit for manufacturing IVD systems, for example, for genotyping applications based on multiplexing using different fluorescent dyes.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Polissacarídeos Bacterianos / Trealose / Primers do DNA / Excipientes / Reação em Cadeia da Polimerase em Tempo Real Idioma: En Revista: Biotechniques Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Polissacarídeos Bacterianos / Trealose / Primers do DNA / Excipientes / Reação em Cadeia da Polimerase em Tempo Real Idioma: En Revista: Biotechniques Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Alemanha