Effect of needle gauge and lobe laterality on parenchymal liver biopsy outcome: a retrospective analysis.
Vijayaraghavan, Gopal R; Vedantham, Srinivasan; Rangan, Vikram; Karam, Adib; Zheng, Larry; Roychowdhury, Abhijit; Hussain, Sarwat.
Afiliação
  • Vijayaraghavan GR; Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA, gopal.vijayaraghavan@umassmemorial.org.
Abdom Imaging ; 40(5): 1223-9, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25367814
PURPOSE: To analyze the effect of lobe selection, needle gauge, and number of passes on procedure outcomes in terms of specimen length and post-procedure complications. METHODS: In this HIPAA-compliant, IRB-approved retrospective study, the data from 771 ultrasound-guided adult parenchymal liver biopsies were analyzed. Post-procedure complications were assigned a 3-point rating scale. Associations between specimen length and post-procedure complications with lobe laterality, needle gauge, and number of passes were analyzed. Multivariate logistic regression models were used to analyze the likelihood for achieving a specimen length of at least 2 cm. RESULTS: Post-procedure complications were not associated with lobe laterality, needle gauge, and number of passes (p > 0.3). Specimen length was associated with the number of passes dichotomized at the study mean (p = 0.007), but not with lobe laterality or needle gauge (p > 0.2). After adjusting for lobe laterality and needle gauge, procedures with 1 or 2 passes were associated with a higher likelihood of obtaining a 2 cm or longer specimen (OR 2.469; CI 1.08-5.63, p = 0.0315) than procedures with 3 or more passes, possibly due to poorer sample quality. After adjusting for lobe laterality, an 18-gauge needle was associated with higher odds of a biopsy procedure with 1 or 2 passes (OR 3.665; CI 1.93-6.95, p < 0.0001) than a 20-gauge needle. CONCLUSIONS: Lobe laterality was not associated with specimen length or post-procedure complications. An 18-gauge needle compared to a 20-gauge needle could reduce the need for a procedure with more than 2 passes. There was no difference in post-procedure complications between the two needle sizes.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Biópsia por Agulha / Fígado Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Abdom Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Biópsia por Agulha / Fígado Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Abdom Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2015 Tipo de documento: Article