Assessment of single-bolus contrast administration technique using hybrid dual-source ECG-gated thoracic and dual-source non-ECG-gated high-pitch abdominopelvic CT acquisitions for procedural planning before transcatheter aortic valve replacement.
Walker, Wendy L; Boll, Daniel T; Bueno, Juliana M; Kiefer, Todd L; Vavalle, John P; Gaca, Jeffrey G; Harrison, J Kevin; Hughes, G Chad; Wang, Andrew; Hurwitz, Lynne M.
Afiliação
  • Walker WL; From the *Department of Radiology, Duke University Medical Center, Durham, NC; †Department of Radiology, University of Virginia Medical Center, Charlottesville, VA; ‡Division of Cardiology, and §Division of Cardiovascular and Thoracic Surgery, Duke University Medical Center, Durham, NC.
J Comput Assist Tomogr ; 39(2): 207-12, 2015.
Article em En | MEDLINE | ID: mdl-25564297
PURPOSE: This study aimed to assess vascular contrast opacification and homogeneity using single-bolus contrast administration with hybrid thoracic and abdominopelvic computed tomographic angiography in patients with severe aortic valve stenosis. MATERIALS AND METHODS: Combination electrocardiogram-gated thoracic and dual-source, high-pitch abdominopelvic computed tomographic angiography examinations of 50 patients with severe aortic stenosis between December 2013 and March 2014 were reviewed. Contrast administration was individualized to patient-specific physiology. Image analysis of vascular opacification was obtained and interdependencies of vascular contrast and homogeneity of contrast distribution were assessed. RESULTS: The mean volume of contrast administered was 106 ± 11.7 mL. Mean attenuation was 371 ± 90.7 Hounsfield units (HU) in the thoracic aorta and 388 ± 95.9 HU in the abdominal aorta. Homogeneous opacification was obtained throughout with coefficient of variation of 11%. CONCLUSIONS: Procedural planning for transcatheter aortic valve replacement can be achieved using a single-injection bolus contrast protocol in combination with a 2-part multidetector computed tomographic image acquisition technique with optimal opacification of major arterial structures.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Cuidados Pré-Operatórios / Tomografia Computadorizada por Raios X / Meios de Contraste / Eletrocardiografia / Substituição da Valva Aórtica Transcateter Tipo de estudo: Evaluation_studies / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Comput Assist Tomogr Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Cuidados Pré-Operatórios / Tomografia Computadorizada por Raios X / Meios de Contraste / Eletrocardiografia / Substituição da Valva Aórtica Transcateter Tipo de estudo: Evaluation_studies / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Comput Assist Tomogr Ano de publicação: 2015 Tipo de documento: Article