Your browser doesn't support javascript.
loading
Observational study of corrected count increments after transfusion of platelets treated with riboflavin pathogen reduction technology in additive solutions.
Drawz, Sarah M; Marschner, Susanne; Yañez, Martha; García de Coca, Alfonso; Feys, Hendrik B; Deeren, Dries; Coene, José.
Afiliação
  • Drawz SM; Department of Lab Medicine and Pathology, University of Minnesota, Minneapolis, Minnesota.
  • Marschner S; Terumo BCT, Lakewood, Colorado.
  • Yañez M; CHEMCYL.
  • García de Coca A; Hospital Clínico Universitario De Valladolid, Valladolid, Spain.
  • Feys HB; Transfusion Research Center, Belgian Red Cross-Flanders, Ghent, Belgium.
  • Deeren D; AZ Delta, Roeselare, Belgium.
  • Coene J; Blood Service of the Belgian Red Cross-Flanders, Mechelen, Belgium.
Transfusion ; 55(7): 1745-51, 2015 Jul.
Article em En | MEDLINE | ID: mdl-25702711
ABSTRACT

BACKGROUND:

Mirasol pathogen reduction technology (PRT) treatment inactivates bacteria, viruses, and parasites in plasma products and platelets (PLTs) suspended in plasma and PLT additive solutions (PAS). Few clinical studies exist documenting transfusions with PAS. This study objective was to evaluate the count increments of PRT-treated PAS-C and PAS-E buffy coat (BC) PLTs in routine use observational settings. STUDY DESIGN AND

METHODS:

PLT pools of five or six BCs were collected, processed, and suspended in PAS-C or PAS-E, respectively. Products were exposed to ultraviolet light in the presence of riboflavin and then transfused into 19 patients with hematologic diseases. Patients were monitored for PLT corrected count increment (CCI) at 1 and 24 hours and for any adverse events in the 72 hours after transfusion. Sterility monitoring was performed with a microbial detection system (BacT/ALERT, bioMérieux).

RESULTS:

The PAS-E products had significantly higher PLT concentrations and counts than the PAS-C products. The mean CCIs of per-protocol (PP) units at 1 and 24 hours were 11,900 (n=27) and 5500 (n=30), respectively. Seventy-eight percent of PP transfusions classify as successful with CCIs at 1 hour of higher than 7500, and 63% higher than 4500 at 24 hours. One patient was excluded from all analyses as she was refractory to Mirasol-treated PLT transfusions and follow-up untreated transfusion products. No adverse events were observed and no contaminated products were detected by BacT/ALERT.

CONCLUSION:

PRT-treated BC PLTs in PAS-C or PAS-E demonstrate PLT transfusion success rates in hematology patients with thrombocytopenia that are comparable to previous studies examining PLTs stored in plasma.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Riboflavina / Preservação de Sangue / Desinfecção / Fármacos Fotossensibilizantes / Transfusão de Plaquetas / Doenças Hematológicas Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Transfusion Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Riboflavina / Preservação de Sangue / Desinfecção / Fármacos Fotossensibilizantes / Transfusão de Plaquetas / Doenças Hematológicas Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Transfusion Ano de publicação: 2015 Tipo de documento: Article