Your browser doesn't support javascript.
loading
Improved Measurement of Blood Pressure by Extraction of Characteristic Features from the Cuff Oscillometric Waveform.
Lim, Pooi Khoon; Ng, Siew-Cheok; Jassim, Wissam A; Redmond, Stephen J; Zilany, Mohammad; Avolio, Alberto; Lim, Einly; Tan, Maw Pin; Lovell, Nigel H.
Afiliação
  • Lim PK; Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. veronicalimpooikhoon@gmail.com.
  • Ng SC; Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. siewcng@um.edu.my.
  • Jassim WA; Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. wissam@um.edu.my.
  • Redmond SJ; Graduate School of Biomedical Engineering, UNSW Australia, Sydney, NSW 2052, Australia. s.redmond@unsw.edu.au.
  • Zilany M; Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. zilany@um.edu.my.
  • Avolio A; Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, NSW 2109, Australia. alberto.avolio@mq.edu.au.
  • Lim E; Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. einly_lim@um.edu.my.
  • Tan MP; Department of Medicine, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur, Malaysia. mptan@ummc.edu.my.
  • Lovell NH; Graduate School of Biomedical Engineering, UNSW Australia, Sydney, NSW 2052, Australia. N.Lovell@unsw.edu.au.
Sensors (Basel) ; 15(6): 14142-61, 2015 Jun 16.
Article em En | MEDLINE | ID: mdl-26087370
ABSTRACT
We present a novel approach to improve the estimation of systolic (SBP) and diastolic blood pressure (DBP) from oscillometric waveform data using variable characteristic ratios between SBP and DBP with mean arterial pressure (MAP). This was verified in 25 healthy subjects, aged 28 ± 5 years. The multiple linear regression (MLR) and support vector regression (SVR) models were used to examine the relationship between the SBP and the DBP ratio with ten features extracted from the oscillometric waveform envelope (OWE). An automatic algorithm based on relative changes in the cuff pressure and neighbouring oscillometric pulses was proposed to remove outlier points caused by movement artifacts. Substantial reduction in the mean and standard deviation of the blood pressure estimation errors were obtained upon artifact removal. Using the sequential forward floating selection (SFFS) approach, we were able to achieve a significant reduction in the mean and standard deviation of differences between the estimated SBP values and the reference scoring (MLR mean ± SD = -0.3 ± 5.8 mmHg; SVR and -0.6 ± 5.4 mmHg) with only two features, i.e., Ratio2 and Area3, as compared to the conventional maximum amplitude algorithm (MAA) method (mean ± SD = -1.6 ± 8.6 mmHg). Comparing the performance of both MLR and SVR models, our results showed that the MLR model was able to achieve comparable performance to that of the SVR model despite its simplicity.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Oscilometria / Pressão Sanguínea / Determinação da Pressão Arterial / Processamento de Sinais Assistido por Computador Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Malásia

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Oscilometria / Pressão Sanguínea / Determinação da Pressão Arterial / Processamento de Sinais Assistido por Computador Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Malásia