Design of a sensitive fluorescent polarization immunoassay for rapid screening of milk for cephalexin.
Beloglazova, Natalia V; Eremin, Sergei A.
Afiliação
  • Beloglazova NV; Faculty of Pharmaceutical Sciences, Laboratory of Food Analysis, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium. natalia.beloglazova@ugent.be.
  • Eremin SA; Faculty of Chemistry, Department of Chemical Enzymology, M.V. Lomonosov Moscow State University, Leninsky Gory 1, 119991, Moscow, Russia.
Anal Bioanal Chem ; 407(28): 8525-32, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26416019
In this paper we describe the development of a sensitive, fast, and easily performed fluorescence polarization immunoassay for determination of cephalexin in milk. The experimental work was performed to increase sensitivity and specificity. Therefore, the structures of the tracers were varied by synthesis of both cephalexin (CEX) and cephalotin (CET) conjugates with a variety of fluorescent labels. Two rabbit antisera containing antibodies against cephalexin and cephalotin were tested in homologous and heterologous combinations with the tracers. For every working antibody-tracer combination, the analytical conditions and cross-reactivity for structural analogues-cephalosporins and other antibiotics that could also be present in milk-were determined. It was found that the highest sensitivity was achieved by use of the homologous pair CET-EDF-anti-CET antibody (limit of detection (LOD) 0.4 µg kg(-1) for standard solutions prepared in buffer), but this combination was not appropriate because of high cross-reactivity with CET. For subsequent experiments, therefore, CEX- EDF-anti-CEX antibody were chosen (LOD 0.8 µg kg(-1) for standard solutions prepared in buffer). Part of this manuscript is devoted to the variation of precipitation agents for pretreatment of milk before analysis; milk is an extremely complicated matrix. The optimum protein precipitation agent was methanol. This technique for cephalexin determination was characterized by a limit of detection of 1 µg kg(-1). The method was validated by using naturally contaminated and spiked milk samples. The results obtained corresponded very well with those obtained by HPLC, which was used as confirmation method.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Resíduos de Drogas / Cefalexina / Cefalotina / Imunoensaio de Fluorescência por Polarização / Leite / Antibacterianos Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Animals / Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Resíduos de Drogas / Cefalexina / Cefalotina / Imunoensaio de Fluorescência por Polarização / Leite / Antibacterianos Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Animals / Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Bélgica