Your browser doesn't support javascript.
loading
Seasonal and spatial evolution of trihalomethanes in a drinking water distribution system according to the treatment process.
Domínguez-Tello, A; Arias-Borrego, A; García-Barrera, Tamara; Gómez-Ariza, J L.
Afiliação
  • Domínguez-Tello A; Department of Chemistry and CC.MM, Faculty of Experimental Science, University of Huelva, Campus de El Carmen, 21007, Huelva, Spain.
  • Arias-Borrego A; International Agrofood Campus of Excellence International CeiA3, University of Huelva, Huelva, Spain.
  • García-Barrera T; Research Center of Health and Environment (CYSMA), University of Huelva, Campus de El Carmen, 21007, Huelva, Spain.
  • Gómez-Ariza JL; Department of Chemistry and CC.MM, Faculty of Experimental Science, University of Huelva, Campus de El Carmen, 21007, Huelva, Spain.
Environ Monit Assess ; 187(11): 662, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26431706
This paper comparatively shows the influence of four water treatment processes on the formation of trihalomethanes (THMs) in a water distribution system. The study was performed from February 2005 to January 2012 with analytical data of 600 samples taken in Aljaraque water treatment plant (WTP) and 16 locations along the water distribution system (WDS) in the region of Andévalo and the coast of Huelva (southwest Spain), a region with significant seasonal and population changes. The comparison of results in the four different processes studied indicated a clear link of the treatment process with the formation of THM along the WDS. The most effective treatment process is preozonation and activated carbon filtration (P3), which is also the most stable under summer temperatures. Experiments also show low levels of THMs with the conventional process of preoxidation with potassium permanganate (P4), delaying the chlorination to the end of the WTP; however, this simple and economical treatment process is less effective and less stable than P3. In this study, strong seasonal variations were obtained (increase of THM from winter to summer of 1.17 to 1.85 times) and a strong spatial variation (1.1 to 1.7 times from WTP to end points of WDS) which largely depends on the treatment process applied. There was also a strong correlation between THM levels and water temperature, contact time and pH. On the other hand, it was found that THM formation is not proportional to the applied chlorine dose in the treatment process, but there is a direct relationship with the accumulated dose of chlorine. Finally, predictive models based on multiple linear regressions are proposed for each treatment process.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Trialometanos / Purificação da Água Tipo de estudo: Prognostic_studies País/Região como assunto: Europa Idioma: En Revista: Environ Monit Assess Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Trialometanos / Purificação da Água Tipo de estudo: Prognostic_studies País/Região como assunto: Europa Idioma: En Revista: Environ Monit Assess Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Espanha