Your browser doesn't support javascript.
loading
Reliable LC-MS quantitative glycomics using iGlycoMab stable isotope labeled glycans as internal standards.
Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia.
Afiliação
  • Zhou S; Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA.
  • Tello N; Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA.
  • Harvey A; GlycoScientific, Athens, GA, USA.
  • Boyes B; GlycoScientific, Athens, GA, USA.
  • Orlando R; GlycoScientific, Athens, GA, USA.
  • Mechref Y; Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA.
Electrophoresis ; 37(11): 1489-97, 2016 06.
Article em En | MEDLINE | ID: mdl-26913967
ABSTRACT
Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Polissacarídeos / Glicômica / Marcação por Isótopo Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Polissacarídeos / Glicômica / Marcação por Isótopo Limite: Humans Idioma: En Revista: Electrophoresis Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos