Your browser doesn't support javascript.
loading
A target field design of open multi-purpose RF coil for musculoskeletal MR imaging at 3T.
Gao, Fei; Zhang, Rui; Zhou, Diange; Wang, Xiaoying; Huang, Kefu; Zhang, Jue.
Afiliação
  • Gao F; College of Engineering, Peking University, Beijing, China.
  • Zhang R; College of Engineering, Peking University, Beijing, China.
  • Zhou D; Arthritis Clinic & Research Center, Peking University People's Hospital, Beijing, China; Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China.
  • Wang X; Department of Radiology, Peking University First Hospital, Beijing, China; Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China.
  • Huang K; College of Engineering, Peking University, Beijing, China. Electronic address: hkf@pku.edu.cn.
  • Zhang J; College of Engineering, Peking University, Beijing, China; Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China. Electronic address: zhangjue@pku.edu.cn.
Magn Reson Imaging ; 34(8): 1064-70, 2016 Oct.
Article em En | MEDLINE | ID: mdl-27114344
Musculoskeletal MR imaging under multi-angle situations plays an increasingly important role in assessing joint and muscle tissues system. However, there are still limitations due to the closed structures of most conventional RF coils. In this study, a time-harmonic target-field method was employed to design open multi-purpose coil (OMC) for multi-angle musculoskeletal MR imaging. The phantom imaging results suggested that the proposed OMC could achieve homogeneously distributed magnetic field and high signal-to-noise ratio (SNR) of 239.04±0.83 in the region of interest (ROI). The maximum temperature in the heating hazard test was 16°C lower than the standard regulation, which indicated the security of the designed OMC. Furthermore, to demonstrate the effectiveness of the proposed OMC for musculoskeletal MR imaging, especially for multi-angle imaging, a healthy volunteer was examined for MR imaging of elbow, ankle and knee using OMC. The in vivo imaging results showed that the proposed OMC is effective for MR imaging of musculoskeletal tissues at different body parts, with satisfied B1 field homogeneity and SNR. Moreover, the open structure of the OMC could provide a large joint movement region. The proposed open multi-purpose coil is feasible for musculoskeletal MR imaging, and potentially, it is more suitable for the evaluation of musculoskeletal tissues under multi-angle conditions.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Articulação do Cotovelo / Articulação do Joelho / Articulação do Tornozelo Limite: Humans Idioma: En Revista: Magn Reson Imaging Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Articulação do Cotovelo / Articulação do Joelho / Articulação do Tornozelo Limite: Humans Idioma: En Revista: Magn Reson Imaging Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China