Analysis of sucrose acetates in a crude 6-O-acetyl sucrose product by on-line hydrolysis-high-performance liquid chromatography with pulsed amperometric detection.
Yan, Wenwu; Wang, Nani; Zhang, Peimin; Zhang, Jiajie; Wu, Shuchao; Zhu, Yan.
Afiliação
  • Yan W; Department of chemistry, Zhejiang University, Hangzhou 310028, China.
  • Wang N; Department of Medicine, Zhejiang Academy of Traditional Chinese Medicine, Hangzhou, 310028, China.
  • Zhang P; Department of chemistry, Zhejiang University, Hangzhou 310028, China.
  • Zhang J; Department of chemistry, Zhejiang University, Hangzhou 310028, China.
  • Wu S; Zhejiang Institute of geology and mineral resources, Hangzhou 310007, China.
  • Zhu Y; Department of chemistry, Zhejiang University, Hangzhou 310028, China. Electronic address: zhuyan@zju.edu.cn.
J Chromatogr A ; 1449: 71-7, 2016 Jun 03.
Article em En | MEDLINE | ID: mdl-27139218
ABSTRACT
A standard-free and sensitive method was developed for analysis of sucrose acetates in a crude 6-O-acetyl sucrose (S-6-a) product by on-line hydrolysis-high-performance liquid chromatography with pulsed amperometric detection (PAD). Sucrose, three regio-isomers of acetyl sucrose and five regio-isomers of diacetyl sucrose were separated on a C18 column using 3% (v/v) acetonitrile in water as eluent within 25min. After purification with LC followed by semi-preparative HPLC, their chemical structures were identified by 1D, 2D NMR and LC-MS. Moreover, quantification of those regio-isomers was achieved by on-line alkaline hydrolysis to liberate sucrose using a post-column delivery system, and then detected by PAD for indirect estimation of the sucrose acetate content. Under optimal conditions, the linear ranges were from 0.03 to 150µmolL(-1) for sucrose corresponding to sucrose acetates with coefficient of determination as 0.9997 and detection limit as 0.01µmolL(-1) (S/N=3). Good repeatability was obtained (RSD<3%, n=6). Furthermore, this method has been successfully applied to the analysis of sucrose and sucrose acetates in a crude S-6-a product during synthesis, purification and structure elucidation studies. The recoveries were from 94.89% to 102.31% for sucrose and sucrose acetates.