Your browser doesn't support javascript.
loading
[Clinical application of MRI histogram in evaluation of muscle fatty infiltration].
Zheng, Y M; Du, J; Li, W Z; Wang, Z X; Zhang, W; Xiao, J X; Yuan, Y.
Afiliação
  • Zheng YM; Department of Neurology, Peking University First Hospital, Beijing 100034, China.
  • Du J; Department of Radiology, Peking University First Hospital, Beijing 100034, China.
  • Li WZ; Department of Neurology, Peking University First Hospital, Beijing 100034, China.
  • Wang ZX; Department of Neurology, Peking University First Hospital, Beijing 100034, China.
  • Zhang W; Department of Neurology, Peking University First Hospital, Beijing 100034, China.
  • Xiao JX; Department of Radiology, Peking University First Hospital, Beijing 100034, China.
Beijing Da Xue Xue Bao Yi Xue Ban ; 48(5): 830-834, 2016 10 18.
Article em Zh | MEDLINE | ID: mdl-27752165
OBJECTIVE: To describe a method based on analysis of the histogram of intensity values produced from the magnetic resonance imaging (MRI) for quantifying the degree of fatty infiltration. METHODS: The study included 25 patients with dystrophinopathy. All the subjects underwent muscle MRI test at thigh level. The histogram M values of 250 muscles adjusted for subcutaneous fat, representing the degree of fatty infiltration, were compared with the expert visual reading using the modified Mercuri scale. RESULTS: There was a significant positive correlation between the histogram M values and the scores of visual reading (r=0.854, P<0.001). The distinct pattern of muscle involvement detected in the patients with dystrophinopathy in our study of histogram M values was similar to that of visual reading and results in literature. The histogram M values had stronger correlations with the clinical data than the scores of visual reading as follows: the correlations with age (r=0.730, P<0.001) and (r=0.753, P<0.001); with strength of knee extensor (r=-0.468, P=0.024) and (r=-0.460, P=0.027) respectively. Meanwhile, the histogram M values analysis had better repeatability than visual reading with the interclass correlation coefficient was 0.998 (95% CI: 0.997-0.998, P<0.001) and 0.958 (95% CI: 0.946-0.967, P<0.001) respectively. CONCLUSION: Histogram M values analysis of MRI with the advantages of repeatability and objectivity can be used to evaluate the degree of muscle fatty infiltration.
Assuntos
Buscar no Google
Bases de dados: MEDLINE Assunto principal: Coxa da Perna / Imageamento por Ressonância Magnética / Bioestatística / Músculo Esquelético / Tecido Adiposo Branco / Distrofias Musculares Limite: Humans Idioma: Zh Revista: Beijing Da Xue Xue Bao Yi Xue Ban Assunto da revista: MEDICINA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China
Buscar no Google
Bases de dados: MEDLINE Assunto principal: Coxa da Perna / Imageamento por Ressonância Magnética / Bioestatística / Músculo Esquelético / Tecido Adiposo Branco / Distrofias Musculares Limite: Humans Idioma: Zh Revista: Beijing Da Xue Xue Bao Yi Xue Ban Assunto da revista: MEDICINA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China