Your browser doesn't support javascript.
loading
Poly (styrene-divinyl benzene-glycidylmethacrylate) stationary phase grafted with poly amidoamine (PAMAM) dendrimers for rapid determination of phenylene diamine isomers in HPLC.
Guo, Dandan; Lou, Chaoyan; Wang, Nani; Chen, Meilan; Zhang, Peimin; Wu, Shuchao; Zhu, Yan.
Afiliação
  • Guo D; Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, China.
  • Lou C; Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, China.
  • Wang N; Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, China; Department of Medicine, Zhejiang Academy of Traditional Chinese Medicine, Hangzhou, Zhejiang, China.
  • Chen M; College of Biology and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015, China.
  • Zhang P; Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, China.
  • Wu S; Zhejiang Institute of Geology and Mineral Resources, Hangzhou 310007, China. Electronic address: wushch2002@163.com.
  • Zhu Y; Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, China. Electronic address: zhuyan@zju.edu.cn.
Talanta ; 168: 188-195, 2017 Jun 01.
Article em En | MEDLINE | ID: mdl-28391841
ABSTRACT
A novel high performance liquid stationary phase was prepared by grafting poly amidoamine (PAMAM) dendrimers to poly (styrene-divinyl benzene-glycidylmethacrylate) matrix in this work. Different generations of PAMAM dendrimers grafted to polymer matrices containing different glycidylmethacrylate amounts by reacting with epoxy groups in glycidylmethacrylate molecules. The synthesized PAMAM dendrimers and stationary phase were characterized by fourier transform infrared spectroscopy, scanning electron microscope, N2 adsorption/desorption, elemental analysis and thermo gravimetric analyzer. The proposed stationary phase was suitable for rapid separation of phenylene diamine isomers and aminobenzene. The separation mechanism of benzene rings attraction and amino repulsion was verified by retention behaviors of methylamine, phenylamine, phenylene diamine, naphthylamine and toluene. The reliability of the stationary phase was demonstrated by separation and determination of phenylene diamine isomers including m-phenylene diamine, o-phenylene diamine and p-phenylene diamine in hair dye precursors within 10min. Satisfactory resolution and short analysis time make the columns promising for determination of aniline compounds in various fields.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2017 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2017 Tipo de documento: Article País de afiliação: China