Your browser doesn't support javascript.
loading
In vitro and ex vivo Measurement of Prophylactic Dabigatran Concentrations with a New Ecarin-Based Thromboelastometry Test.
Körber, Mareike Kristina; Langer, Elisabeth; Köhr, Martin; Wernecke, Klaus-Dieter; Korte, Wolfgang; von Heymann, Christian.
Afiliação
  • Körber MK; Department of Anesthesiology and Intensive Care Medicine, Charité -Universitätsmedizin Berlin, Campus Virchow-Klinikum, Berlin, Germany.
  • Langer E; Labor Berlin - Charite Vivantes GmbH Berlin, Berlin, Germany.
  • Köhr M; Institute for Laboratory Medicine, Clinical Chemistry and Pathobiochemistry, Charité - Universitätsmedizin Berlin, Campus Virchow-Klinikum, Berlin, Germany.
  • Wernecke KD; Department of Anesthesiology and Intensive Care Medicine, Charité -Universitätsmedizin Berlin, Campus Virchow-Klinikum, Berlin, Germany.
  • Korte W; SOSTANA GmbH, Berlin, Germany.
  • von Heymann C; Center for Laboratory Medicine; and Hemostasis and Hemophilia Center St. Gallen, Switzerland.
Transfus Med Hemother ; 44(2): 100-105, 2017 Apr.
Article em En | MEDLINE | ID: mdl-28503126
BACKGROUND: An increasing number of oral anticoagulants has been approved, including dabigatran etexilate (DE). DE is a direct thrombin inhibitor that requires no routine monitoring, but, if necessary (e.g. urgent surgery etc.), the diluted thrombin time measured with Hemoclot® has shown reliable results. So far, no point-of-care (PoC) assay is available to measure DE effects. The EcaTEM assay uses ecarin to initiate the coagulation cascade at the step of thrombin generation and measures the clotting time (CT) by thromboelastometry. METHODS: This study investigated the correlation of the EcaTEM with standard laboratory assays in dabigatran-treated patients. Ten patients undergoing total hip or knee arthroplasty were included in the study. DE for thromboprophylaxis was started 4 h after surgery. Blood samples were taken before surgery as well as 2, 6 and 12 h after ingestion on the 3rd postoperative day. Dabigatran concentration (Hemoclot), activated partial thromboplastin time, thrombin time and CT EcaTEM were measured. RESULTS: Only CT EcaTEM and Hemoclot showed a correlation > 0.75 for all measurements. CONCLUSION: CT EcaTEM appears a valid PoC method parameter to detect thrombin inhibition and thus the presence of dabigatran beside diluted thrombin time at different concentration levels. This may represent an opportunity to identify the presence of dabigatran, e.g., in emergency situations.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Transfus Med Hemother Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Transfus Med Hemother Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha