Your browser doesn't support javascript.
loading
Physical Activity Measured by Implanted Devices Predicts Atrial Arrhythmias and Patient Outcome: Results of IMPLANTED (Italian Multicentre Observational Registry on Patients With Implantable Devices Remotely Monitored).
Palmisano, Pietro; Guerra, Federico; Ammendola, Ernesto; Ziacchi, Matteo; Luigi Pisanò, Ennio Carmine; Dell'Era, Gabriele; Aspromonte, Vittorio; Zaccaria, Maria; Di Ubaldo, Francesco; Capucci, Alessandro; Nigro, Gerardo; Occhetta, Eraldo; Maglia, Giampiero; Ricci, Renato Pietro; Boriani, Giuseppe; Accogli, Michele.
Afiliação
  • Palmisano P; Cardiology Unit "Card. G. Panico" Hospital, Tricase, Italy dr.palmisano@libero.it.
  • Guerra F; Cardiology and Arrhythmology Clinic, Marche Polytechnic University University Hospital "Umberto I-Lancisi-Salesi,", Ancona, Italy.
  • Ammendola E; Department of Cardiology, Monaldi Hospital Second University of Naples, Italy.
  • Ziacchi M; Institute of Cardiology, University of Bologna S.Orsola-Malpighi University Hospital, Bologna, Italy.
  • Luigi Pisanò EC; "Vito Fazzi" Hospital, Lecce, Italy.
  • Dell'Era G; Division of Cardiology, University of Eastern Piedmont Maggiore della Carità Hospital, Novara, Italy.
  • Aspromonte V; Cardiology-Coronary Care Unit, Pugliese-Ciaccio Hospital, Catanzaro, Italy.
  • Zaccaria M; Cardiology Unit "Card. G. Panico" Hospital, Tricase, Italy.
  • Di Ubaldo F; Cardiology and Arrhythmology Clinic, Marche Polytechnic University University Hospital "Umberto I-Lancisi-Salesi,", Ancona, Italy.
  • Capucci A; Cardiology and Arrhythmology Clinic, Marche Polytechnic University University Hospital "Umberto I-Lancisi-Salesi,", Ancona, Italy.
  • Nigro G; Department of Cardiology, Monaldi Hospital Second University of Naples, Italy.
  • Occhetta E; Division of Cardiology, University of Eastern Piedmont Maggiore della Carità Hospital, Novara, Italy.
  • Maglia G; Cardiology-Coronary Care Unit, Pugliese-Ciaccio Hospital, Catanzaro, Italy.
  • Ricci RP; Department of Cardiovascular Diseases, San Filippo Neri Hospital, Rome, Italy.
  • Boriani G; Cardiology Department, University of Modena and Reggio Emilia Policlinico di Modena, Italy.
  • Accogli M; Cardiology Unit "Card. G. Panico" Hospital, Tricase, Italy.
J Am Heart Assoc ; 7(5)2018 02 24.
Article em En | MEDLINE | ID: mdl-29478022
ABSTRACT

BACKGROUND:

To determine whether daily physical activity (PA), as measured by implanted devices (through accelerometer sensor), was related to the risk of developing atrial arrhythmias during long-term follow-up in a population of heart failure (HF) patients with an implantable cardioverter defibrillator (ICD). METHODS AND

RESULTS:

The study population was divided into 2 equally sized groups (PA cutoff point 3.5 h/d) according to their mean daily PA recorded by the device during the 30- to 60-day period post-ICD implantation. Propensity score matching was used to compare 2 equally sized cohorts with similar characteristics between lower and higher activity patients. The primary end point was time free from the first atrial high-rate episode (AHRE) of duration ≥6 minutes. Secondary end points were first AHRE ≥6 hours, first AHRE ≥48 hours, and a combined end point of death or HF hospitalization. Data from 770 patients (65±15 years; 66% men; left ventricular ejection fraction 35±12%) remotely monitored for a median of 25 months were analyzed. A PA ≥3.5 h/d was associated with a 38% relative reduction in the risk of AHRE ≥6 minutes (72-month cumulative survival 75.0% versus 68.1%; log rank P=0.025), and with a reduction in the risk of AHRE ≥6 hours, AHRE ≥48 hours, and the combined end point of death or HF hospitalization (all P<0.05).

CONCLUSIONS:

In HF patients with ICD, a low level of daily PA was associated with a higher risk of atrial arrhythmias, regardless of the patients' baseline characteristics. In addition, a lower daily PA predicted death or HF hospitalization.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Fibrilação Atrial / Cardioversão Elétrica / Exercício Físico / Desfibriladores Implantáveis / Actigrafia / Tecnologia de Sensoriamento Remoto / Monitores de Aptidão Física / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: J Am Heart Assoc Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Fibrilação Atrial / Cardioversão Elétrica / Exercício Físico / Desfibriladores Implantáveis / Actigrafia / Tecnologia de Sensoriamento Remoto / Monitores de Aptidão Física / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: J Am Heart Assoc Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália