Your browser doesn't support javascript.
loading
Outcomes of patients requiring extracorporeal membrane oxygenation in transcatheter aortic valve implantation: a clinical case series.
Higuchi, Ryosuke; Tobaru, Tetsuya; Hagiya, Kenichi; Saji, Mike; Takamisawa, Itaru; Shimizu, Jun; Iguchi, Nobuo; Takanashi, Shuichiro; Takayama, Morimasa; Isobe, Mitsuaki.
Afiliação
  • Higuchi R; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan. rhiguchi@shi.heart.or.jp.
  • Tobaru T; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Hagiya K; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Saji M; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Takamisawa I; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Shimizu J; Department of Anesthesiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Iguchi N; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Takanashi S; Department of Cardiovascular Surgery, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Takayama M; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
  • Isobe M; Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu, Tokyo, 183-0003, Japan.
Heart Vessels ; 33(11): 1343-1349, 2018 Nov.
Article em En | MEDLINE | ID: mdl-29721672
ABSTRACT
Transcatheter aortic valve implantation (TAVI) has been established as a low-invasive therapy for aortic stenosis, but circulatory collapse necessitating mechanical circulatory support could occur during TAVI due to procedure itself or procedural complications. The purpose of this study is to describe the outcomes of patients requiring extracorporeal membrane oxygenation (ECMO) in TAVI. Among 384 consecutive patients undergoing TAVI from April 2010 to July 2017 in Sakakibara Heart Institute, we evaluated seven patients (1.8%) who required ECMO during procedure. The definitions of outcome were derived from Valve Academic Research Consortium-2 criteria. The indication of ECMO included bridge to emergent surgery due to mechanical complication (n = 3) [aortic root rupture (n = 2), and left-ventricle rupture (n = 1); emergent use], bridge to recovery from cardiac stunning (n = 3; emergent use), and circulatory support for cardiogenic shock (n = 1; prophylactic use). All patients were cannulated from femoral artery and vein, and there was no ECMO-related complication. Six out of seven patients were weaned from ECMO during the TAVI procedure, whereas the other patient with annulus rupture died the following day after TAVI. Five patients survived to discharge [postoperative hospital stay 27.6 ± 24.3 (23) days]. During mean follow-up of 253 days, a total of three patients died due to annulus rupture, refractory heart failure, and pneumonia, respectively. ECMO is effective and a safe mechanical support device during TAVI. The mid-term outcomes of patients who needed ECMO were unfavorable. Further evolution of transcatheter heart valve is essential, and prophylactic ECMO may contribute to better prognosis in selected patients.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Complicações Pós-Operatórias / Próteses Valvulares Cardíacas / Oxigenação por Membrana Extracorpórea / Medição de Risco / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans / Male País/Região como assunto: Asia Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Complicações Pós-Operatórias / Próteses Valvulares Cardíacas / Oxigenação por Membrana Extracorpórea / Medição de Risco / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans / Male País/Região como assunto: Asia Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão