Your browser doesn't support javascript.
loading
Regulatory context and validation of assays for clinical mass spectrometry proteomics (cMSP) methods.
Hirtz, Christophe; Bros, Pauline; Brede, Cato; Lescuyer, Pierre; Maceski, Aleksandra M; Vialaret, Jerome; Delatour, Vincent; Lehmann, Sylvain.
Afiliação
  • Hirtz C; a CHU Montpellier, IRMB, Hôpital Saint Eloi, LBPC et CRB, University of Montpellier , Montpellier , France.
  • Bros P; a CHU Montpellier, IRMB, Hôpital Saint Eloi, LBPC et CRB, University of Montpellier , Montpellier , France.
  • Brede C; b Laboratoire National de Métrologie et d'Essais (LNE) , Paris , France.
  • Lescuyer P; c Stavanger University Hospital, Avdeling for Medisinsk Biokjemi , Stavanger , Norway.
  • Maceski AM; d Laboratoire de Toxicologie et de Suivi Thérapeutique des Médicaments, Service de Médecine de Laboratoire, Hôpitaux Universitaires de Genève , Gèneve , Switzerland.
  • Vialaret J; a CHU Montpellier, IRMB, Hôpital Saint Eloi, LBPC et CRB, University of Montpellier , Montpellier , France.
  • Delatour V; a CHU Montpellier, IRMB, Hôpital Saint Eloi, LBPC et CRB, University of Montpellier , Montpellier , France.
  • Lehmann S; b Laboratoire National de Métrologie et d'Essais (LNE) , Paris , France.
Crit Rev Clin Lab Sci ; 55(5): 346-358, 2018 08.
Article em En | MEDLINE | ID: mdl-29792094
ABSTRACT
Clinical mass spectrometry proteomics (cMSP) assays are being increasingly used in clinical laboratories for analyzing peptides and proteins. It has therefore become urgent to characterize and validate the methods available for liquid chromatography-tandem mass spectrometry (LC/MS-MS) targeted quantification of peptide and protein biomarkers in biological fluids in the context of in vitro diagnostics. LC-MS/MS for the detection of peptides and proteins is currently the main approach used in the field of cMSP. As a result of their selectivity, low reagent costs and the fact that these methods can be used for absolute quantification and multiplexing, they will likely eventually replace immunoassays. Although LC-MS/MS is known to be the main reference method involved in reference measurement procedures (RMPs), it needs to meet the requirements of in vitro diagnostic (IVD) regulations and standards. This review shows that cMSP is fully compatible with the regulatory IVD requirements and provides an overview of the characterization and validation of the use of LC-MS/MS targeted quantification of clinical protein biomarkers in biological fluids.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Espectrometria de Massas / Cromatografia Líquida / Técnicas de Laboratório Clínico / Proteômica Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Crit Rev Clin Lab Sci Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Espectrometria de Massas / Cromatografia Líquida / Técnicas de Laboratório Clínico / Proteômica Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Crit Rev Clin Lab Sci Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França