Integrated athermal arrayed-waveguide grating multiplexer and demultiplexer with all-metal compensating rod for broadband temperature application.
Appl Opt ; 57(21): 6207-6212, 2018 Jul 20.
Article em En | MEDLINE | ID: mdl-30118001
ABSTRACT
In this paper, a unique device that can act as both multiplexer and demultiplexer is proposed with two all-metal compensating rods that makes the compensated chip almost the same spectrum profile as the original one. In this way a flat-top athermal arrayed-waveguide grating module of 100-GHz×40-ch is successfully fabricated. A small center wavelength shift of ±25 pm is achieved for the ultra-wide temperature range from -40°C to 85°C with the low insertion loss change of less than ±0.14 dB.

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Appl Opt Ano de publicação: 2018 Tipo de documento: Article