Life cycle assessment of a commercial rainwater harvesting system compared with a municipal water supply system.
Ghimire, Santosh R; Johnston, John M; Ingwersen, Wesley W; Sojka, Sarah.
Afiliação
  • Ghimire SR; ORISE Postdoctoral Research Participant, U.S. Environmental Protection Agency, Office of Research and Development, 960 College Station Rd., Athens, GA 30605, USA.
  • Johnston JM; U.S. Environmental Protection Agency, Office of Research and Development, 960 College Station Rd., Athens, GA 30605, USA.
  • Ingwersen WW; U.S. Environmental Protection Agency, Office of Research and Development, 26 W. Martin Luther King Dr., Cincinnati, OH 45268, USA.
  • Sojka S; Randolph College, 2500 Rivermont Ave., Lynchburg, VA 24503, USA.
J Clean Prod ; 151: 74-86, 2017 May 10.
Article em En | MEDLINE | ID: mdl-30147248
ABSTRACT
Building upon previously published life cycle assessment (LCA) methodologies, we conducted an LCA of a commercial rainwater harvesting (RWH) system and compared it to a municipal water supply (MWS) system adapted to Washington, D.C. Eleven life cycle impact assessment (LCIA) indicators were assessed, with a functional unit of 1 m3 of rainwater and municipal water delivery system for toilets and urinals in a four-story commercial building with 1000 employees. Our assessment shows that the benchmark commercial RWH system outperforms the MWS system in all categories except Ozone Depletion. Sensitivity and performance analyses revealed pump and pumping energy to be key components for most categories, which further guides LCIA tradeoff analysis with respect to energy intensities. Tradeoff analysis revealed that commercial RWH performed better than MWS in Ozone Depletion if RWH's energy intensity was less than that of MWS by at least 0.86 kWh/m3 (249% of the benchmark MWS energy usage at 0.35 kWh/m3). RWH also outperformed MWS in Metal Depletion and Freshwater Withdrawal, regardless of energy intensities, up to 5.51 kWh/m3. An auxiliary commercial RWH system with 50% MWS reduced Ozone Depletion by 19% but showed an increase in all other impacts, which were still lower than benchmark MWS system impacts. Current models are transferrable to commercial RWH installations at other locations.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: J Clean Prod Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos