Your browser doesn't support javascript.
loading
Initial stability and stress distribution of ankle arthroscopic arthrodesis with three kinds of 2-screw configuration fixation: a finite element analysis.
Zhu, Min; Yuan, Cheng-Song; Jin, Zhong-Min; Wang, Yun-Jiao; Shi, You-Xing; Yang, Zhi-Jin; Tang, Kanglai.
Afiliação
  • Zhu M; Department of Orthopaedic Surgery, Southwest Hospital, The Third Military Medical University, Gaotanyan Str. 30, Chongqing city, 400038, People's Republic of China.
  • Yuan CS; Department of Orthopaedic Surgery, Southwest Hospital, The Third Military Medical University, Gaotanyan Str. 30, Chongqing city, 400038, People's Republic of China.
  • Jin ZM; School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, Sichuan, China.
  • Wang YJ; Department of Orthopaedic Surgery, Southwest Hospital, The Third Military Medical University, Gaotanyan Str. 30, Chongqing city, 400038, People's Republic of China.
  • Shi YX; Department of Orthopaedic Surgery, Southwest Hospital, The Third Military Medical University, Gaotanyan Str. 30, Chongqing city, 400038, People's Republic of China.
  • Yang ZJ; Department of Orthopaedic Surgery, Southwest Hospital, The Third Military Medical University, Gaotanyan Str. 30, Chongqing city, 400038, People's Republic of China.
  • Tang K; Department of Orthopaedic Surgery, Southwest Hospital, The Third Military Medical University, Gaotanyan Str. 30, Chongqing city, 400038, People's Republic of China. tangkanglai@hotmail.com.
J Orthop Surg Res ; 13(1): 263, 2018 Oct 20.
Article em En | MEDLINE | ID: mdl-30342526
ABSTRACT

BACKGROUND:

Arthroscopic ankle arthrodesis (AAA) is recognized as the standard treatment for the end-stage ankle arthritis. Two-screw configuration fixation is a typical technique for AAA; however, no consensus has been reached on how to select most suitable inserted position and direction. For better joint reduction, we developed a new configuration (2 home run-screw configuration 2 screws are inserted from the lateral-posterior and medial-posterior malleolus into the talar neck) and investigated whether it turned out to be better than the other commonly used 2-screw configurations.

METHODS:

In this study, we investigated three kinds of 2-screw configurations 2 "home run"-screw configuration (group A), crossed transverse configuration (the screw is inserted from the medial malleolus into the anterior talus and the other from the lateral tibia maintains posterior talus, group B), and 2 parallel screw configuration (2 parallel screws are inserted from the posteromedial side of the tibia into talus, group C). The effects of the above three insertions on the loading stress of the tibio-talar joint were comparatively analyzed with a three-dimensional finite element model.

RESULTS:

Group A was better than groups B and C in respect of stress distribution uniformity and superior to both groups B and C in anti-flexion strength and anti-internal rotation strength. Group A was slightly worse than group C but better than group B in anti-dorsiflexion and anti-valgus and varus strength.

CONCLUSIONS:

Two "home run"-screw configuration facilitates the reduction of anterior talus dislocation of end-stage ankle arthritis. Our finite element analysis demonstrates the configuration is superior to crossed transverse and parallel configuration for arthroscopic ankle arthrodesis in terms of stress distribution and initial stability.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Artrite / Artrodese / Parafusos Ósseos / Articulação do Tornozelo Limite: Adult / Humans / Male Idioma: En Revista: J Orthop Surg Res Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Artrite / Artrodese / Parafusos Ósseos / Articulação do Tornozelo Limite: Adult / Humans / Male Idioma: En Revista: J Orthop Surg Res Ano de publicação: 2018 Tipo de documento: Article