Your browser doesn't support javascript.
loading
Evaluation of analytical performances using standardized analytical protocols and comparison of clinical results of the new ADVIA BNP and NT-proBNP immunoassays for the Centaur XPT platform.
Masotti, Silvia; Musetti, Veronica; Prontera, Concetta; Storti, Simona; Ndreu, Rudina; Passino, Claudio; Zucchelli, Giancarlo; Clerico, Aldo.
Afiliação
  • Masotti S; Scuola Superiore Sant'Anna, Fondazione G. Monasterio CNR - Regione Toscana, Pisa, Italy.
  • Musetti V; Scuola Superiore Sant'Anna, Fondazione G. Monasterio CNR - Regione Toscana, Pisa, Italy.
  • Prontera C; Scuola Superiore Sant'Anna, Fondazione G. Monasterio CNR - Regione Toscana, Pisa, Italy.
  • Storti S; Scuola Superiore Sant'Anna, Fondazione G. Monasterio CNR - Regione Toscana, Pisa, Italy.
  • Ndreu R; CNR Institute of Clinical Physiology and QualiMedLab, Pisa, Italy.
  • Passino C; Scuola Superiore Sant'Anna, Fondazione G. Monasterio CNR - Regione Toscana, Pisa, Italy.
  • Zucchelli G; CNR Institute of Clinical Physiology and QualiMedLab, Pisa, Italy.
  • Clerico A; Scuola, Superiore Sant'Anna, Department of Laboratory Medicine, Fondazione G. Monasterio CNR - Regione Toscana, Via Giuseppe Moruzzi 1, 56124 Pisa, Italy.
Clin Chem Lab Med ; 57(6): 911-917, 2019 05 27.
Article em En | MEDLINE | ID: mdl-30412461
ABSTRACT
Background The study aim was to evaluate and compare analytical performances and clinical results of ADVIA BNP and PBNP methods using the Centaur XPT platform with those of Access BNP, using the DxI platform and the ECLIA NT-proBNP method, using the Cobas e411 platform, respectively. Methods Limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 20% CV and 10% CV were evaluated according to international standardized protocols. The analytical parameters were assessed throughout a 90-working-day period using three curve calibrations. Results LoB, LoD and LoQ at 20% CV and 10% values of the ADVIA BNP method were 1.0 ng/L, 2.0 ng/L, 3.7 ng/L and 10.2 ng/L, respectively; while those of the ADVIA PBNP method were 1.3 ng/L, 3.0 ng/L, 9.7 ng/L and 22.3 ng/L, respectively. The ADVIA BNP and PBNP methods were able to measure the clinical decision values suggested by international guidelines for diagnosis of heart failure (HF) with an imprecision ≤6%. BNP concentrations measured with the ADVIA and Access methods showed a close linear regression (R=0.9923, n=200); a close linear regression was also found between NT-proBNP concentrations measured with the ADVIA and ECLIA methods (R=0.9954, n=202). However, the ADVIA method measured significantly lower BNP values than the Access method (on average -20.9%), while ADVIA PBNP method measured significantly higher NT-proBNP concentrations than the ECLIA method (on average +17.8%). Conclusions Analytical performances of the BNP and PBNP ADVIA methods are well in accordance with the quality specifications required by international guidelines for diagnosis and follow-up of patients with HF.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Imunoensaio / Peptídeo Natriurético Encefálico Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Imunoensaio / Peptídeo Natriurético Encefálico Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Itália