Your browser doesn't support javascript.
loading
Application of miniSTR Loci and Its Detection System for Degraded Materials in Forensic Medicine.
Wang, Xin; Chen, W Z; Zhang, J; Li, J H; Sun, Y P; Shi, Y J; Zhang, L; Chen, L L; Zhou, X; Zhou, R H.
Afiliação
  • Wang X; Institute of Forensic Science, Suzhou Public Security Bureau, Suzhou 215131, Jiangsu Province, China.
  • Chen WZ; Institute of Forensic Science, Suzhou Public Security Bureau, Suzhou 215131, Jiangsu Province, China.
  • Zhang J; Institute of Forensic Science, Suzhou Public Security Bureau, Suzhou 215131, Jiangsu Province, China.
  • Li JH; Institute of Forensic Science, Suzhou Public Security Bureau, Suzhou 215131, Jiangsu Province, China.
  • Sun YP; Institute of Forensic Science, Suzhou Public Security Bureau, Suzhou 215131, Jiangsu Province, China.
  • Shi YJ; Institute of Forensic Science, Suzhou Public Security Bureau, Suzhou 215131, Jiangsu Province, China.
  • Zhang L; AGCU ScienTech Incorporation, Wuxi 214174, Jiangsu Province, China.
  • Chen LL; AGCU ScienTech Incorporation, Wuxi 214174, Jiangsu Province, China.
  • Zhou X; AGCU ScienTech Incorporation, Wuxi 214174, Jiangsu Province, China.
  • Zhou RH; Institute of Forensic Science, Suzhou Public Security Bureau, Suzhou 215131, Jiangsu Province, China.
Fa Yi Xue Za Zhi ; 34(5): 532-537, 2018 Oct.
Article em En, Zh | MEDLINE | ID: mdl-30468058
ABSTRACT

OBJECTIVES:

To establish multiplex system of 16 miniSTR loci, and explore its application value for the degraded materials in forensic medicine.

METHODS:

The multiplex system of 16 miniSTR loci was established using a six-dye fluorescence labeling technology and its application value in forensic medicine was assessed.

RESULTS:

A six-dye fluorescence labeling miniSTR amplification kit was developed, which enabled 15 autosomal STR loci, Amelogenin locus and DYS391 to be typed simultaneously. This method showed good specificity and could provide stable and accurate typing results with a sensitivity of 50 pg. This system also provided a good test result for the normal biological sample of actual cases.

CONCLUSIONS:

The multiplex system of 16 miniSTR loci has application value for degraded and trace materials with the advantages of high sensitivity and database compatibility, which can be used for forensic casework.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Reação em Cadeia da Polimerase / Impressões Digitais de DNA / Repetições de Microssatélites Tipo de estudo: Diagnostic_studies Idioma: En / Zh Revista: Fa Yi Xue Za Zhi Assunto da revista: JURISPRUDENCIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Reação em Cadeia da Polimerase / Impressões Digitais de DNA / Repetições de Microssatélites Tipo de estudo: Diagnostic_studies Idioma: En / Zh Revista: Fa Yi Xue Za Zhi Assunto da revista: JURISPRUDENCIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China