Your browser doesn't support javascript.
loading
Seventeen to Twenty Years of Follow-Up of the Low Contact Stress Rotating-Platform Total Knee Arthroplasty With a Cementless Tibia in All Cases.
McMahon, Samuel E; Doran, Emer; O'Brien, Seamus; Cassidy, Roslyn S; Boldt, Jens G; Beverland, David E.
Afiliação
  • McMahon SE; Outcomes Unit, Primary Joint Unit, Department of Orthopaedics, Musgrave Park Hospital, Belfast, United Kingdom.
  • Doran E; Outcomes Unit, Primary Joint Unit, Department of Orthopaedics, Musgrave Park Hospital, Belfast, United Kingdom.
  • O'Brien S; Outcomes Unit, Primary Joint Unit, Department of Orthopaedics, Musgrave Park Hospital, Belfast, United Kingdom.
  • Cassidy RS; Outcomes Unit, Primary Joint Unit, Department of Orthopaedics, Musgrave Park Hospital, Belfast, United Kingdom.
  • Boldt JG; Department of Orthopaedics, OrthoBoldt AG, Bern, Switzerland.
  • Beverland DE; Outcomes Unit, Primary Joint Unit, Department of Orthopaedics, Musgrave Park Hospital, Belfast, United Kingdom.
J Arthroplasty ; 34(3): 508-512, 2019 03.
Article em En | MEDLINE | ID: mdl-30553560
BACKGROUND: Total knee arthroplasty designs can be categorized by bearing design and fixation method. The mobile-bearing concept was developed with the aim of increasing longevity and improving function by reduced polyethylene wear and closer replication of physiological knee motion. Cementless fixation has the goal of achieving a long-lasting "biological" fixation between prosthesis and bone. METHODS: Prospective analysis of the survivorship and patient-reported functional outcomes of a series of 500 low contact stress rotating-platform mobile-bearing total knee arthroplasties with a cementless tibial component with a minimum 17-year follow-up. RESULTS: Five hundred primary total knee arthroplasties were conducted in 467 patients. Mean follow-up was 18.1 (17.0-21.8) years and 141 (28.2%) knees were alive and available for review. Using revision for any cause as the end point, cumulative survivorship was 97.4%. Thirteen knees required revision: 3 for deep infection, 3 bearing only revisions for spinout, 3 for tibial tray subsidence, 2 secondary patella resurfacings, 1 aseptic loosening, and 1 for suspected aseptic loosening that was found to be well fixed. Mean American Knee Society Scores were 83 (evaluation) and 48 (function), Mean Oxford Knee Score was 32.1, and the mean Bartlett Patellar Score was 21.6. CONCLUSION: This series demonstrates excellent survivorship and acceptable patient-reported functional outcome scores of a mobile-bearing total knee arthroplasty with a cementless tibial tray at minimum 17-year follow-up.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Tíbia / Artroplastia do Joelho / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Tíbia / Artroplastia do Joelho / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido