Clotting factor activity in fresh frozen plasma after thawing with a new radio wave thawing device.
Kuta, Piotr; Melling, Nathaniel; Zimmermann, Robert; Achenbach, Susanne; Eckstein, Reinhold; Strobel, Julian.
Afiliação
  • Kuta P; Thrombosis & Hemostasis Treatment Center, Institute of Clinical Chemistry, University Hospital Schleswig Holstein, Kiel, Germany.
  • Melling N; Department of Surgery, University Hospital Eppendorf, Hamburg, Germany.
  • Zimmermann R; Department of Transfusion Medicine and Hemostaseology, University Hospital Erlangen, Friedrich-Alexander-University, Erlangen, Germany.
  • Achenbach S; Department of Transfusion Medicine and Hemostaseology, University Hospital Erlangen, Friedrich-Alexander-University, Erlangen, Germany.
  • Eckstein R; Department of Transfusion Medicine and Hemostaseology, University Hospital Erlangen, Friedrich-Alexander-University, Erlangen, Germany.
  • Strobel J; Department of Transfusion Medicine and Hemostaseology, University Hospital Erlangen, Friedrich-Alexander-University, Erlangen, Germany.
Transfusion ; 59(5): 1857-1861, 2019 05.
Article em En | MEDLINE | ID: mdl-30883784
BACKGROUND: Massive hemorrhage usually results in rapid need of blood products. Patients in need of fresh frozen plasma (FFP) might benefit from shorter thawing times using a novel radio wave device. So far, only one study on the prototype has been published. Activities of clotting factors after thawing FFP with the radio wave device and with a system using water cushions were compared. This is the first study analyzing the quality of FFP using the fully developed radio wave thawing device UFT100. STUDY DESIGN AND METHODS: Thirty FFP units were thawed with the UFT100 and the Plasmatherm machine. Various clotting factors and inhibitors were analyzed before freezing, immediately after thawing, and after a 48-hour storage period at +4°C. RESULTS: After thawing, all factor activities were within normal ranges regardless of the thawing procedure. We observed significant differences in nearly all clotting factor activities regarding time as effector, whereas thawing with the Plasmatherm machine led to a significant decrease (>10%) only in factor V activity compared to the UFT100. CONCLUSIONS: Immediately after rapid thawing with the UFT100, all FFP units contained adequate coagulation factor activities to maintain hemostatic activity. The UFT100 does not deteriorate FFP quality compared to a conventional system. Regardless of the thawing system, the postthaw refrigerated storage caused a decrease in several clotting factors and inhibitors (factors V, VIII, and IX; von Willebrand factor activity; protein S and C activity) and a significant increase of factor XI.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Plasma / Ondas de Rádio / Fatores de Coagulação Sanguínea Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Transfusion Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Plasma / Ondas de Rádio / Fatores de Coagulação Sanguínea Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Transfusion Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha