Your browser doesn't support javascript.
loading
Efficacy of the proximal optimization technique on crossover stenting in coronary bifurcation lesions in the 3D-OCT bifurcation registry.
Murasato, Yoshinobu; Mori, Takahiro; Okamura, Takayuki; Nagoshi, Ryoji; Fujimura, Tatsuhiro; Yamawaki, Masahiro; Ono, Shiro; Serikawa, Takeshi; Nakao, Fumiaki; Shite, Junya.
Afiliação
  • Murasato Y; Department of Cardiology & Clinical Research Center, National Hospital Organization, Kyusyu Medical Center, 1-8-1, Jigyohama, Chuo, Fukuoka, 810-8563, Japan. y.murasato@gmail.com.
  • Mori T; Department of Cardiology & Clinical Research Center, National Hospital Organization, Kyusyu Medical Center, 1-8-1, Jigyohama, Chuo, Fukuoka, 810-8563, Japan.
  • Okamura T; Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine, Ube, Japan.
  • Nagoshi R; Department of Cardiology, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan.
  • Fujimura T; Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine, Ube, Japan.
  • Yamawaki M; Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan.
  • Ono S; Department of Cardiology, Saiseikai Yamaguchi General Hospital, Yamaguchi, Japan.
  • Serikawa T; Department of Cardiology, Saiseikai Fukuoka General Hospital, Fukuoka, Japan.
  • Nakao F; Department of Cardiology, Yamaguchi Grand Medical Center, Hofu, Japan.
  • Shite J; Department of Cardiology, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan.
Int J Cardiovasc Imaging ; 35(6): 981-990, 2019 Jun.
Article em En | MEDLINE | ID: mdl-30887408
AIM: We sought to investigate the efficacy of the proximal optimization technique (POT) on crossover stenting followed by side branch (SB) dilation under optical coherence tomography guidance in a multicenter registry study. METHODS AND RESULTS: A total of 135 bifurcation lesions in 134 patients were divided into POT (n = 52) and non-POT groups (n = 83). The POT was performed before SB dilatation (pre-POT; n = 26), finally (final-POT; n = 12), at both timing (re-POT; n = 13), and uncertain (n = 1). There were no significant intergroup differences in the success rate of guide wire re-crossing (GWR) into the optimal cell (72% vs. 65%), incidence of the link-free type in the configuration of the SB jailed struts (51% vs. 49%), or incomplete strut apposition at the bifurcation (13 ± 11% vs. 10 ± 9%). However, insufficient stent expansion close to the carina in the proximal main vessel (MV) due to inappropriate POT was likely to induce greater incomplete strut apposition (ISA) around the bifurcation. Only re-POT provided more symmetric proximal MV expansion, while pre- and final-POT did not. CONCLUSION: The POT did not provide the expected beneficial effects, such as reduction of ISA or more optimal GWR, under the OCT guidance. Wide stent expansion in the proximal MV induced by the POT increased the likelihood of achieving optimal GWR, whereas symmetric stent expansion was provided by re-POT.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Stents / Vasos Coronários / Imageamento Tridimensional / Estenose Coronária / Tomografia de Coerência Óptica / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Stents / Vasos Coronários / Imageamento Tridimensional / Estenose Coronária / Tomografia de Coerência Óptica / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão