Your browser doesn't support javascript.
loading
Development and clinical validation of a non-invasive, beat-to-beat blood pressure monitoring device, compared to invasive blood pressure monitoring during coronary angiography.
Borges, Melania Aparecida; Prado, Marcelo; Santini, Tales Roberto de Souza; Barbosa, Adriano Henrique Pereira; Moreira, Antonio Carlos; Ishibe, Eder Issao; Katz, Marcelo; Cintra, Fatima Dumas.
Afiliação
  • Borges MA; Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Prado M; Universidade de São Paulo, São Carlos, SP, Brazil.
  • Santini TRS; University of Pittsburgh, Pittsburgh, PA, United States.
  • Barbosa AHP; Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Moreira AC; Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Ishibe EI; Universidade de São Paulo, São Carlos, SP, Brazil.
  • Katz M; Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
  • Cintra FD; Universidade Federal de São Paulo, São Paulo, SP, Brazil.
Einstein (Sao Paulo) ; 17(2): eAO4156, 2019 Mar 18.
Article em En, Pt | MEDLINE | ID: mdl-30892376
OBJECTIVE: To develop and test a beat-to-beat blood pressure monitoring device during coronary angiography, and compare it with invasive blood pressure monitoring. METHODS: Twenty-eight patients with an indication for hemodynamic study were selected for this investigation, and kept in supine position. Before starting the coronary angiography, they were instructed about the use of the left radial bracelet for beat-to-beat blood pressure monitoring. RESULTS: There was a significant difference between the time required for the catheterization laboratory team to acquire the first invasive blood pressure reading and the time to obtain the first beat-to-beat reading (11.1±5.1 and 1.5±1.8, respectively; p<0.0001). The intraclass correlation coefficients (95%CI) of systolic and diastolic blood pressures were 0.897 (0.780-0.952) and 0.876 (0.734-0.942), indicating good reproducibility. CONCLUSION: This study showed the process to develop a beat-to-beat blood pressure monitoring device. When compared to invasive blood pressure monitoring, there were no significant differences between the two methods. This technique may play a promising coadjuvant role when combined with invasive monitoring during coronary angiography procedures.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Monitores de Pressão Arterial / Angiografia Coronária Limite: Female / Humans / Male / Middle aged Idioma: En / Pt Revista: Einstein (Sao Paulo) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Monitores de Pressão Arterial / Angiografia Coronária Limite: Female / Humans / Male / Middle aged Idioma: En / Pt Revista: Einstein (Sao Paulo) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil