In vivo demonstration of microscopic anisotropy in the human kidney using multidimensional diffusion MRI.
Nery, Fabio; Szczepankiewicz, Filip; Kerkelä, Leevi; Hall, Matt G; Kaden, Enrico; Gordon, Isky; Thomas, David L; Clark, Chris A.
Afiliação
  • Nery F; Developmental Imaging and Biophysics Section, UCL Great Ormond Street Institute of Child Health, London, United Kingdom.
  • Szczepankiewicz F; Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts.
  • Kerkelä L; Harvard Medical School, Boston, Massachusetts.
  • Hall MG; Medical Radiation Physics, Clinical Sciences, Lund, Lund University, Lund, Sweden.
  • Kaden E; Developmental Imaging and Biophysics Section, UCL Great Ormond Street Institute of Child Health, London, United Kingdom.
  • Gordon I; Developmental Imaging and Biophysics Section, UCL Great Ormond Street Institute of Child Health, London, United Kingdom.
  • Thomas DL; National Physical Laboratory, Teddington, United Kingdom.
  • Clark CA; Centre for Medical Image Computing, University College London, London, United Kingdom.
Magn Reson Med ; 82(6): 2160-2168, 2019 12.
Article em En | MEDLINE | ID: mdl-31243814
PURPOSE: To demonstrate the feasibility of multidimensional diffusion MRI to probe and quantify microscopic fractional anisotropy (µFA) in human kidneys in vivo. METHODS: Linear tensor encoded (LTE) and spherical tensor encoded (STE) renal diffusion MRI scans were performed in 10 healthy volunteers. Respiratory triggering and image registration were used to minimize motion artefacts during the acquisition. Kidney cortex-medulla were semi-automatically segmented based on fractional anisotropy (FA) values. A model-free analysis of LTE and STE signal dependence on b-value in the renal cortex and medulla was performed. Subsequently, µFA was estimated using a single-shell approach. Finally, a comparison of conventional FA and µFA is shown. RESULTS: The hallmark effect of µFA (divergence of LTE and STE signal with increasing b-value) was observed in all subjects. A statistically significant difference between LTE and STE signal was found in the cortex and medulla, starting from b = 750 s/mm2 and b = 500 s/mm2 , respectively. This difference was maximal at the highest b-value sampled (b = 1000 s/mm2 ) which suggests that relatively high b-values are required for µFA mapping in the kidney compared to conventional FA. Cortical and medullary µFA were, respectively, 0.53 ± 0.09 and 0.65 ± 0.05, both respectively higher than conventional FA (0.19 ± 0.02 and 0.40 ± 0.02). CONCLUSION: The feasibility of combining LTE and STE diffusion MRI to probe and quantify µFA in human kidneys is demonstrated for the first time. By doing so, we show that novel microstructure information-not accessible by conventional diffusion encoding-can be probed by multidimensional diffusion MRI. We also identify relevant technical limitations that warrant further development of the technique for body MRI.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Anisotropia / Imagem de Difusão por Ressonância Magnética / Rim Limite: Adult / Female / Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Anisotropia / Imagem de Difusão por Ressonância Magnética / Rim Limite: Adult / Female / Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido