Your browser doesn't support javascript.
loading
Intra-Abdominal Hypertension Is Responsible for False Negatives to the Passive Leg Raising Test.
Beurton, Alexandra; Teboul, Jean-Louis; Girotto, Valentina; Galarza, Laura; Anguel, Nadia; Richard, Christian; Monnet, Xavier.
Afiliação
  • Beurton A; Service de médecine intensive-réanimation, Hôpital de Bicêtre, Hôpitaux universitaires Paris-Sud, Assistance publique - Hôpitaux de Paris, Le Kremlin-Bicêtre, France.
  • Teboul JL; Inserm UMR S_999, Université Paris-Sud, Le Kremlin-Bicêtre, France.
  • Girotto V; Service de médecine intensive-réanimation, Hôpital de Bicêtre, Hôpitaux universitaires Paris-Sud, Assistance publique - Hôpitaux de Paris, Le Kremlin-Bicêtre, France.
  • Galarza L; Inserm UMR S_999, Université Paris-Sud, Le Kremlin-Bicêtre, France.
  • Anguel N; Service de médecine intensive-réanimation, Hôpital de Bicêtre, Hôpitaux universitaires Paris-Sud, Assistance publique - Hôpitaux de Paris, Le Kremlin-Bicêtre, France.
  • Richard C; Service de médecine intensive-réanimation, Hôpital de Bicêtre, Hôpitaux universitaires Paris-Sud, Assistance publique - Hôpitaux de Paris, Le Kremlin-Bicêtre, France.
  • Monnet X; Service de médecine intensive-réanimation, Hôpital de Bicêtre, Hôpitaux universitaires Paris-Sud, Assistance publique - Hôpitaux de Paris, Le Kremlin-Bicêtre, France.
Crit Care Med ; 47(8): e639-e647, 2019 08.
Article em En | MEDLINE | ID: mdl-31306258
OBJECTIVES: To compare the passive leg raising test ability to predict fluid responsiveness in patients with and without intra-abdominal hypertension. DESIGN: Observational study. SETTING: Medical ICU. PATIENTS: Mechanically ventilated patients monitored with a PiCCO2 device (Pulsion Medical Systems, Feldkirchen, Germany) in whom fluid expansion was planned, with (intra-abdominal hypertension+) and without (intra-abdominal hypertension-) intra-abdominal hypertension, defined by an intra-abdominal pressure greater than or equal to 12 mm Hg (bladder pressure). INTERVENTIONS: We measured the changes in cardiac index during passive leg raising and after volume expansion. The passive leg raising test was defined as positive if it increased cardiac index greater than or equal to 10%. Fluid responsiveness was defined by a fluid-induced increase in cardiac index greater than or equal to 15%. MEASUREMENTS AND MAIN RESULTS: We included 60 patients, 30 without intra-abdominal hypertension (15 fluid responders and 15 fluid nonresponders) and 30 with intra-abdominal hypertension (21 fluid responders and nine fluid nonresponders). The intra-abdominal pressure at baseline was 4 ± 3 mm Hg in intra-abdominal hypertension- and 20 ± 6 mm Hg in intra-abdominal hypertension+ patients (p < 0.01). In intra-abdominal hypertension- patients with fluid responsiveness, cardiac index increased by 25% ± 19% during passive leg raising and by 35% ± 14% after volume expansion. The passive leg raising test was positive in 14 patients. The passive leg raising test was negative in all intra-abdominal hypertension- patients without fluid responsiveness. In intra-abdominal hypertension+ patients with fluid responsiveness, cardiac index increased by 10% ± 14% during passive leg raising (p = 0.01 vs intra-abdominal hypertension- patients) and by 32% ± 18% during volume expansion (p = 0.72 vs intra-abdominal hypertension- patients). Among these patients, the passive leg raising test was negative in 15 patients (false negatives) and positive in six patients (true positives). Among the nine intra-abdominal hypertension+ patients without fluid responsiveness, the passive leg raising test was negative in all but one patient. The area under the receiver operating characteristic curve of the passive leg raising test for detecting fluid responsiveness was 0.98 ± 0.02 (p < 0.001 vs 0.5) in intra-abdominal hypertension- patients and 0.60 ± 0.11 in intra-abdominal hypertension+ patients (p = 0.37 vs 0.5). CONCLUSIONS: Intra-abdominal hypertension is responsible for some false negatives to the passive leg raising test.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Reações Falso-Negativas / Hipertensão Intra-Abdominal / Perna (Membro) / Monitorização Fisiológica Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Reações Falso-Negativas / Hipertensão Intra-Abdominal / Perna (Membro) / Monitorização Fisiológica Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: França