Your browser doesn't support javascript.
loading
Feasibility of automated detection of sleep apnea using implantable pacemakers and defibrillators: a comparison with simultaneous polysomnography recording.
Della Rocca, Domenico G; Albanese, Maria; Placidi, Fabio; Forle, Giovanni B; Di Biase, Luigi; Ribatti, Valentina; Santini, Luca; Izzi, Francesca; Cicchini, Lucia; Lovecchio, Mariolina; Valsecchi, Sergio; Lavalle, Carlo; Natale, Andrea; Mercuri, Nicola B; Romigi, Andrea.
Afiliação
  • Della Rocca DG; Texas Cardiac Arrhythmia Institute, St. David's Medical Center, 3000 N IH-35, Suite 720, Austin, TX, 78705, USA. domenicodellarocca@hotmail.it.
  • Albanese M; Sleep Disorders Centre, Neurophysiopathology Unit, Department of Systems Medicine, University of Rome "Tor Vergata", Rome, Italy.
  • Placidi F; Sleep Disorders Centre, Neurophysiopathology Unit, Department of Systems Medicine, University of Rome "Tor Vergata", Rome, Italy.
  • Forle GB; Azienda Ospedaliera - Polo Universitario - "Luigi Sacco", Milan, Italy.
  • Di Biase L; Texas Cardiac Arrhythmia Institute, St. David's Medical Center, 3000 N IH-35, Suite 720, Austin, TX, 78705, USA.
  • Ribatti V; Albert Einstein College of Medicine, Montefiore Hospital, New York, USA.
  • Santini L; Department of Biomedical Engineering, University of Texas, Austin, TX, USA.
  • Izzi F; Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy.
  • Cicchini L; Cardiac Arrhythmia Research Center, Centro Cardiologico Monzino, IRCCS, Università di Milano, Milan, Italy.
  • Lovecchio M; G.B. Grassi Hospital, Ostia, Rome, Italy.
  • Valsecchi S; Sleep Disorders Centre, Neurophysiopathology Unit, Department of Systems Medicine, University of Rome "Tor Vergata", Rome, Italy.
  • Lavalle C; Department of Cardiovascular Medicine, University of Tor Vergata, Rome, Italy.
  • Natale A; CRM Department, Boston Scientific Italy, Viale Forlanini 23, 20134, Milan, Italy.
  • Mercuri NB; CRM Department, Boston Scientific Italy, Viale Forlanini 23, 20134, Milan, Italy.
  • Romigi A; Department of Cardiovascular, Respiratory, Nephrology, Anesthesiology and Geriatric Sciences, "Sapienza" University of Rome, Policlinico "Umberto" I, Rome, Italy.
J Interv Card Electrophysiol ; 56(3): 327-333, 2019 Dec.
Article em En | MEDLINE | ID: mdl-31646429
PURPOSE: Sleep-related breathing disorders (SRBD) have been associated with adverse cardiovascular events and prognosis. Some modern pacemakers (PMK) and implantable cardioverter defibrillators (ICD) are equipped with thoracic impedance monitoring systems which allow detecting fluctuations in tidal volume occurring in SRBD. This study aimed at assessing the accuracy of a novel transthoracic impedance-based PMK/ICD sensor for automatic detection of SRBD. METHODS: We prospectively enrolled 31 consecutive patients scheduled for implantation of a PMK or an ICD with sleep respiratory disturbances monitoring capability. The results of unattended home nocturnal recordings expressed as apnea/hypopnea index (AHI) were compared with the respiratory disturbance index (RDI) stored in the cardiac device memory at the time polygraphy was performed. RESULTS: Among the 31 enrolled patients (20 men, mean age 70 ± 8 years), a comparison between the data from polygraphy and cardiac device was feasible in 29 patients. According to the results of home nocturnal recording, a severe SRBD was observed in 7/29 (24.1%) patients. On the basis of receiver-operating characteristic curve analysis of RDI values, the optimal RDI cutoff value to identify severe SRBD was 47 episodes/h (sensitivity 100%, specificity 100%). Bland-Altman agreement analysis of AHI-RDI revealed a bias between measurements of - 11 episodes/h, with limits of agreement - 38 to 15 episodes/h. CONCLUSIONS: In the present study, the novel transthoracic impedance-based monitoring system ApneaScanTM appeared effective in screening PMK and ICD patients for SRBD.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Síndromes da Apneia do Sono / Polissonografia / Desfibriladores Implantáveis Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Interv Card Electrophysiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Síndromes da Apneia do Sono / Polissonografia / Desfibriladores Implantáveis Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Interv Card Electrophysiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Estados Unidos