Your browser doesn't support javascript.
loading
The Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects.
Fujiwara, Shunrou; Sato, Shinpei; Sugawara, Atsushi; Nishikawa, Yasumasa; Koji, Takahiro; Nishimura, Yukihide; Ogasawara, Kuniaki.
Afiliação
  • Fujiwara S; Department of Neurosurgery, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3695, Japan.
  • Sato S; Institute for Open and Transdisciplinary Research Initiative, Osaka University, 3-1 Yamadaoka, Suita, Osaka 565-0871, Japan.
  • Sugawara A; Department of Neurosurgery, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3695, Japan.
  • Nishikawa Y; Department of Neurosurgery, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3695, Japan.
  • Koji T; Department of Neurosurgery, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3695, Japan.
  • Nishimura Y; Department of Neurosurgery, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3695, Japan.
  • Ogasawara K; Department of Rehabilitation Medicine, Iwate Medical University, 1-1-1 Idaidori, Yahaba, Iwate 028-3695, Japan.
Sensors (Basel) ; 20(3)2020 Jan 21.
Article em En | MEDLINE | ID: mdl-31972959
ABSTRACT
The aim of this study was to investigate whether variation in gait-related parameters among healthy participants could help detect gait abnormalities. In total, 36 participants (21 men, 15 women; mean age, 35.7 ± 9.9 years) performed a 10-m walk six times while wearing a tri-axial accelerometer fixed at the L3 level. A second walk was performed ≥1 month after the first (mean interval, 49.6 ± 7.6 days). From each 10-m data set, the following nine gait-related parameters were automatically calculated assessment time, number of steps, stride time, cadence, ground force reaction, step time, coefficient of variation (CV) of step time, velocity, and step length. Six repeated measurement values were averaged for each gait parameter. In addition, for each gait parameter, the difference between the first and second assessments was statistically examined, and the intraclass correlation coefficient (ICC) was calculated with the level of significance set at p < 0.05. Only the CV of step time showed a significant difference between the first and second assessments (p = 0.0188). The CV of step time also showed the lowest ICC, at <0.50 (0.425), among all parameters. Test-retest results of gait assessment using a tri-axial accelerometer showed sufficient reproducibility in terms of the clinical evaluation of all parameters except the CV of step time.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Acelerometria / Marcha Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Acelerometria / Marcha Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão