ABSTRACT

OBJECTIVES:

Most of cardiac dedicated CZT-SPECT systems are not equipped with CT, whereas PET systems are. We evaluated the impact of AC correction on CZT-SPECT myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements.

METHODS:

104 patients were included. SPECT data were acquired on cadmium zinc telluride (CZT)-based pinhole cardiac camera in listmode using a stress (250 ± 17 MBq)/rest (511 ± 23 MBq) 1-day Tc-99m-tetrofosmin protocol. Low-dose CT was acquired on another SPECT/CT camera in the same position. All analysis was performed using Corridor4DM.

RESULTS:

Stress and rest MBF were significantly lower when AC was applied (P < 0.001). For regional and global MFR, there was no significant difference between AC and NAC measurements (P > 0.25 at least). Mean global LV MFR was 2.43 ± 0.87 and 2.33 ± 0.89, respectively, for NAC and AC measurements. Using a threshold of 2, 86 patients (83%) remained classified as normal and abnormal regarding global LV MFR whether AC was applied or not. Mean difference between NAC and AC values for the 18 other patients was 0.3.

CONCLUSION:

AC correction does not significantly affect MFR measurement both in regional and global LV analyses.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Telúrio / Zinco / Cádmio / Tomografia Computadorizada de Emissão de Fóton Único / Circulação Coronária / Imagem de Perfusão do Miocárdio Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Telúrio / Zinco / Cádmio / Tomografia Computadorizada de Emissão de Fóton Único / Circulação Coronária / Imagem de Perfusão do Miocárdio Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França