Right ventricular assessment in patients undergoing transcatheter or surgical aortic valve replacement.
Catheter Cardiovasc Interv
; 96(7): E711-E722, 2020 12.
Article
em En
| MEDLINE
| ID: mdl-32198810
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative treatment option to surgical aortic valve replacement (SAVR) in selected high-risk patients. In this study, we aimed to evaluate the prognostic value of right ventricular (RV) functional imaging to predict clinical response to TAVR and SAVR. METHODS: One hundred and ten patients with symptomatic severe aortic valve stenosis (AVS) undergoing successful TAVR and 32 controls undergoing SAVR were prospectively enrolled. Six months follow up (FU) included two-dimensional (2D) transthoracic echocardiography (TTE) with RV deformation imaging. RESULTS: Baseline TTE showed no significant differences between groups (TAVR and SAVR) in conventional left ventricular (LV) and RV functional parameters (LV ejection fraction [LV-EF]: p = .21; tricuspidal annular plane systolic excursion [TAPSE]: 1.8 ± 0.5 cm, 1.9 ± 0.4 cm, p = .21), and RV strain (right ventricular-global longitudinal strain [RV-GLS] -11.6 ± 5.2%, -11.5 ± 6.5%, p = .70). At FU LV function was unchanged in both groups (p > .05); RV function was significantly improved after TAVR (RV-GLS: -11.6 ± 5.2%, -13.4 ± 6.1%, p = .005; TAPSE: 1.8 ± 0.5 cm, 1.9 ± 0.3 cm, p = .05), and worsened after SAVR (RV-GLS: -11.5 ± 6.5%, -8.9 ± 5.2%, p = .04; TAPSE: 1.9 ± 0.4 cm, 1.5 ± 0.3 cm, p < .001). Functional New York Heart Association (NYHA) class remained unchanged in patients after SAVR (p = .21), and improved after TAVR (p < .001). Baseline RV function was linked with clinical response to TAVR (TAPSE, p < .0001; RV-GLS, p = .04), and the development of RV-GLS was associated with functional worsening after SAVR (p = .05). CONCLUSION: Baseline RV function and changes of right heart mechanics are closely associated with functional improvements after AVR. SAVR, but not TAVR, seems to have detrimental effects on RV-function.
Palavras-chave
Texto completo:
1
Bases de dados:
MEDLINE
Assunto principal:
Valva Aórtica
/
Estenose da Valva Aórtica
/
Ecocardiografia Doppler
/
Função Ventricular Direita
/
Implante de Prótese de Valva Cardíaca
/
Substituição da Valva Aórtica Transcateter
Tipo de estudo:
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Catheter Cardiovasc Interv
Assunto da revista:
CARDIOLOGIA
Ano de publicação:
2020
Tipo de documento:
Article
País de afiliação:
Alemanha