Your browser doesn't support javascript.
loading
A Simple and Quick Solution to the Retained Traumatic Urethral Catheter.
Georgiades, F; Bakewell, R; Tsiotras, A.
Afiliação
  • Georgiades F; Department of Surgery, University of Cambridge, Cambridge, UK. Electronic address: fg391@cam.ac.uk.
  • Bakewell R; Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Tsiotras A; Department of Urology, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
Urology ; 141: e39-e40, 2020 Jul.
Article em En | MEDLINE | ID: mdl-32305541
A misplaced urinary catheter within the bulbar urethra in a medically complex patient could not be removed due to an undeflatable balloon. Simple bedside measures including flexible cystoscopy were unsuccessful in deflating this. Here we describe a simple and quick solution to this stressful situation using a transperineal ultrasound guided puncture. This method should be considered when the retained traumatic catheter lies distal to the prostate gland.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Uretra / Remoção de Dispositivo / Cateteres Urinários / Corpos Estranhos Limite: Aged / Humans / Male Idioma: En Revista: Urology Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Uretra / Remoção de Dispositivo / Cateteres Urinários / Corpos Estranhos Limite: Aged / Humans / Male Idioma: En Revista: Urology Ano de publicação: 2020 Tipo de documento: Article