Your browser doesn't support javascript.
loading
4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease.
Lenz, Alexander; Petersen, Johannes; Riedel, Christoph; Weinrich, Julius M; Kooijman, Hendrik; Schoennagel, Bjoern P; Adam, Gerhard; von Kodolitsch, Yskert; Reichenspurner, Hermann; Girdauskas, Evaldas; Bannas, Peter.
Afiliação
  • Lenz A; Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany. a.lenz@uke.de.
  • Petersen J; Department of Cardiovascular Surgery, University Heart Center, Hamburg, Germany.
  • Riedel C; Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
  • Weinrich JM; Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
  • Kooijman H; Clinical Science Department, Philips GmbH, Hamburg, Germany.
  • Schoennagel BP; Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
  • Adam G; Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
  • von Kodolitsch Y; Department of Cardiology, University Heart Center, Hamburg, Germany.
  • Reichenspurner H; Department of Cardiovascular Surgery, University Heart Center, Hamburg, Germany.
  • Girdauskas E; Department of Cardiovascular Surgery, University Heart Center, Hamburg, Germany.
  • Bannas P; Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
J Cardiovasc Magn Reson ; 22(1): 29, 2020 04 30.
Article em En | MEDLINE | ID: mdl-32354361

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Aorta Torácica / Valva Aórtica / Insuficiência da Valva Aórtica / Aortografia / Interpretação de Imagem Assistida por Computador / Imagem Cinética por Ressonância Magnética / Anuloplastia da Valva Cardíaca / Doenças das Valvas Cardíacas / Hemodinâmica Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Aorta Torácica / Valva Aórtica / Insuficiência da Valva Aórtica / Aortografia / Interpretação de Imagem Assistida por Computador / Imagem Cinética por Ressonância Magnética / Anuloplastia da Valva Cardíaca / Doenças das Valvas Cardíacas / Hemodinâmica Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha