Your browser doesn't support javascript.
loading
Combined simultaneous multislice bSSFP and compressed sensing for first-pass myocardial perfusion at 1.5 T with high spatial resolution and coverage.
McElroy, Sarah; Ferrazzi, Giulio; Nazir, Muhummad Sohaib; Kunze, Karl P; Neji, Radhouene; Speier, Peter; Stäb, Daniel; Forman, Christoph; Razavi, Reza; Chiribiri, Amedeo; Roujol, Sébastien.
Afiliação
  • McElroy S; School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom.
  • Ferrazzi G; School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom.
  • Nazir MS; School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom.
  • Kunze KP; MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom.
  • Neji R; School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom.
  • Speier P; MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom.
  • Stäb D; Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany.
  • Forman C; MR Research Collaborations, Siemens Healthcare Pty Ltd, Melbourne, Australia.
  • Razavi R; Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany.
  • Chiribiri A; School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom.
  • Roujol S; School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom.
Magn Reson Med ; 84(6): 3103-3116, 2020 12.
Article em En | MEDLINE | ID: mdl-32530064

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imagem de Perfusão do Miocárdio Tipo de estudo: Observational_studies / Qualitative_research Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Imagem de Perfusão do Miocárdio Tipo de estudo: Observational_studies / Qualitative_research Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Reino Unido