Time to Loss of Preoxygenation in Emergency Department Patients.
Mosier, Jarrod; Reardon, Robert F; DeVries, Paige A; Stang, Jamie L; Nelsen, Ashley; Prekker, Matthew E; Driver, Brian E.
Afiliação
  • Mosier J; Department of Emergency Medicine and Department of Medicine, Division of Pulmonary, Allergy, Critical Care and Sleep, University of Arizona College of Medicine, Tucson, Arizona.
  • Reardon RF; Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota.
  • DeVries PA; Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota.
  • Stang JL; Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota.
  • Nelsen A; Albany Medical College, Albany, New York.
  • Prekker ME; Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota; Division of Pulmonary/Critical Care, Department of Medicine, Hennepin County Medical Center, Minneapolis, Minnesota.
  • Driver BE; Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota.
J Emerg Med ; 59(5): 637-642, 2020 Nov.
Article em En | MEDLINE | ID: mdl-32771321
ABSTRACT

BACKGROUND:

In patients requiring emergency rapid sequence intubation (RSI), 100% oxygen is often delivered for preoxygenation to replace alveolar nitrogen with oxygen. Sometimes, however, preoxygenation devices are prematurely removed from the patient prior to the onset of apnea, which can lead to rapid loss of preoxygenation.

OBJECTIVE:

We sought to determine the elapsed time, on average, between removing the oxygen source and the loss of preoxygenation among non-critically ill patients in the emergency department (ED).

METHODS:

We conducted a prospective, crossover study of non-critically ill patients in the ED. Each patient received two identical preoxygenation trials for 4 min using a non-rebreather mask with oxygen flow at flush rate and a nasal cannula with oxygen flow at 10 L/min. After each preoxygenation trial, patients underwent two trials in random order while continuing spontaneous breathing 1) removal of both oxygen sources and 2) removal of non-rebreather mask with nasal cannula left in place. We defined loss of preoxygenation as an end-tidal oxygen (exhaled oxygen percentage; EtO2) value < 70%. We measured EtO2 breath by breath until loss of preoxygenation occurred.

RESULTS:

We enrolled 42 patients, median age was 43 years (interquartile range [IQR] 30 to 54 years) and 72% were male. Median time to loss of preoxygenation was 20 s (IQR 17-25 s, 4.5 breaths) when all oxygen devices were removed, and 39 s (IQR 21-56 s, 8 breaths) when the nasal cannula was left in place.

CONCLUSIONS:

In this population of non-critically ill ED patients, most had loss of preoxygenation after 5 breaths if all oxygen devices were removed, and after 8 breaths if a nasal cannula was left in place. These data suggest that during ED RSI, preoxygenation devices should be left in place until the patient is completely apneic.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Respiração Artificial / Cânula Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Emerg Med Assunto da revista: MEDICINA DE EMERGENCIA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Respiração Artificial / Cânula Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Emerg Med Assunto da revista: MEDICINA DE EMERGENCIA Ano de publicação: 2020 Tipo de documento: Article