Your browser doesn't support javascript.
loading
Comparative evaluation of two commercial real-time PCR kits (QuantiFast™ and abTES™) for the detection of Plasmodium knowlesi and other Plasmodium species in Sabah, Malaysia.
Nuin, Nor Afizah; Tan, Angelica F; Lew, Yao Long; Piera, Kim A; William, Timothy; Rajahram, Giri S; Jelip, Jenarun; Dony, Jiloris F; Mohammad, Rashidah; Cooper, Daniel J; Barber, Bridget E; Anstey, Nicholas M; Chua, Tock H; Grigg, Matthew J.
Afiliação
  • Nuin NA; Faculty of Medicine and Health Sciences, Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia.
  • Tan AF; Infectious Diseases Society Kota Kinabalu - Menzies School of Health Research Clinical Research Unit, Kota Kinabalu, Sabah, Malaysia. angelicafiona.tan@menzies.edu.au.
  • Lew YL; Global and Tropical Health Division, Menzies School of Health Research, Charles Darwin University, Darwin, PO Box 41096, Casuarina, NT, 0810, Australia. angelicafiona.tan@menzies.edu.au.
  • Piera KA; Infectious Diseases Society Kota Kinabalu - Menzies School of Health Research Clinical Research Unit, Kota Kinabalu, Sabah, Malaysia.
  • William T; Infectious Diseases Society Kota Kinabalu - Menzies School of Health Research Clinical Research Unit, Kota Kinabalu, Sabah, Malaysia.
  • Rajahram GS; Global and Tropical Health Division, Menzies School of Health Research, Charles Darwin University, Darwin, PO Box 41096, Casuarina, NT, 0810, Australia.
  • Jelip J; Infectious Diseases Society Kota Kinabalu - Menzies School of Health Research Clinical Research Unit, Kota Kinabalu, Sabah, Malaysia.
  • Dony JF; Gleneagles Hospital, Kota Kinabalu, Sabah, Malaysia.
  • Mohammad R; Clinical Research Centre, Queen Elizabeth Hospital, Ministry of Health, Kota Kinabalu, Sabah, Malaysia.
  • Cooper DJ; Infectious Diseases Society Kota Kinabalu - Menzies School of Health Research Clinical Research Unit, Kota Kinabalu, Sabah, Malaysia.
  • Barber BE; Clinical Research Centre, Queen Elizabeth Hospital, Ministry of Health, Kota Kinabalu, Sabah, Malaysia.
  • Anstey NM; Ministry of Health, Kuala Lumpur, Malaysia.
  • Chua TH; State Public Health Laboratory, Sabah Department of Health, Kota Kinabalu, Malaysia.
  • Grigg MJ; State Public Health Laboratory, Sabah Department of Health, Kota Kinabalu, Malaysia.
Malar J ; 19(1): 306, 2020 Aug 27.
Article em En | MEDLINE | ID: mdl-32854695
ABSTRACT

BACKGROUND:

The monkey parasite Plasmodium knowlesi is an emerging public health issue in Southeast Asia. In Sabah, Malaysia, P. knowlesi is now the dominant cause of human malaria. Molecular detection methods for P. knowlesi are essential for accurate diagnosis and in monitoring progress towards malaria elimination of other Plasmodium species. However, recent commercially available PCR malaria kits have unpublished P. knowlesi gene targets or have not been evaluated against clinical samples.

METHODS:

Two real-time PCR methods currently used in Sabah for confirmatory malaria diagnosis and surveillance reporting were evaluated the QuantiFast™ Multiplex PCR kit (Qiagen, Germany) targeting the P. knowlesi 18S SSU rRNA; and the abTES™ Malaria 5 qPCR II kit (AITbiotech, Singapore), with an undisclosed P. knowlesi gene target. Diagnostic accuracy was evaluated using 52 P. knowlesi, 25 Plasmodium vivax, 21 Plasmodium falciparum, and 10 Plasmodium malariae clinical isolates, and 26 malaria negative controls, and compared against a validated reference nested PCR assay. The limit of detection (LOD) for each PCR method and Plasmodium species was also evaluated.

RESULTS:

The sensitivity of the QuantiFast™ and abTES™ assays for detecting P. knowlesi was comparable at 98.1% (95% CI 89.7-100) and 100% (95% CI 93.2-100), respectively. Specificity of the QuantiFast™ and abTES™ for P. knowlesi was high at 98.8% (95% CI 93.4-100) for both assays. The QuantiFast™ assay demonstrated falsely-positive mixed Plasmodium species at low parasitaemias in both the primary and LOD analysis. Diagnostic accuracy of both PCR kits for detecting P. vivax, P. falciparum, and P. malariae was comparable to P. knowlesi. The abTES™ assay demonstrated a lower LOD for P. knowlesi of ≤ 0.125 parasites/µL compared to QuantiFast™ with a LOD of 20 parasites/µL. Hospital microscopy demonstrated a sensitivity of 78.8% (95% CI 65.3-88.9) and specificity of 80.4% (95% CI 67.6-89.8) compared to reference PCR for detecting P. knowlesi.

CONCLUSION:

The QuantiFast™ and abTES™ commercial PCR kits performed well for the accurate detection of P. knowlesi infections. Although the QuantiFast™ kit is cheaper, the abTES™ kit demonstrated a lower LOD, supporting its use as a second-line referral-laboratory diagnostic tool in Sabah, Malaysia.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Plasmodium knowlesi / Testes Diagnósticos de Rotina / Reação em Cadeia da Polimerase em Tempo Real / Monitoramento Epidemiológico Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Malar J Assunto da revista: MEDICINA TROPICAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Malásia

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Plasmodium knowlesi / Testes Diagnósticos de Rotina / Reação em Cadeia da Polimerase em Tempo Real / Monitoramento Epidemiológico Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Malar J Assunto da revista: MEDICINA TROPICAL Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Malásia