Your browser doesn't support javascript.
loading
A 3-axis coil design for multichannel TMS arrays.
Navarro de Lara, Lucia I; Daneshzand, Mohammad; Mascarenas, Anthony; Paulson, Douglas; Pratt, Kevin; Okada, Yoshio; Raij, Tommi; Makarov, Sergey N; Nummenmaa, Aapo.
Afiliação
  • Navarro de Lara LI; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Charlestown, MA 02129, USA. Electronic address: lnavarrodelara@mgh.harvard.edu.
  • Daneshzand M; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Charlestown, MA 02129, USA.
  • Mascarenas A; Tristan Technologies, San Diego, CA 92121, USA.
  • Paulson D; Tristan Technologies, San Diego, CA 92121, USA.
  • Pratt K; Tristan Technologies, San Diego, CA 92121, USA.
  • Okada Y; Moment Technologies LLC, Charlestown, MA, USA.
  • Raij T; Center for Brain Stimulation, Shirley Ryan AbilityLab, Chicago IL 60611 USA; Department of Physical Medicine and Rehabilitation, Department of Neurobiology, Northwestern University, Chicago IL 60611 USA.
  • Makarov SN; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Charlestown, MA 02129, USA; Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609, USA.
  • Nummenmaa A; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Charlestown, MA 02129, USA. Electronic address: anummenmaa@mgh.harvard.edu.
Neuroimage ; 224: 117355, 2021 01 01.
Article em En | MEDLINE | ID: mdl-32916290
PURPOSE: Multichannel Transcranial Magnetic Stimulation (mTMS) arrays enable multiple sites to be stimulated simultaneously or sequentially under electronic control without moving the system's stimulation coils. Here, we build and characterize the performance of a novel modular 3-axis TMS coil that can be utilized as a unit element in large-scale multichannel TMS arrays. METHODS: We determined the basic physical characteristics of the 3-axis TMS coil x-, y- and z-elements using a custom 2-channel programmable stimulator prototype. We mapped the temporal rate-of-change of the induced magnetic field (dB/dt) on a 2D plane parallel to the coil surface (including an extended line for full spatial coverage) and compared those values with predictions from magnetic field simulations. Temperature measurements were carried out to assess the incorporated air-cooling method. We measured the mutual and self-inductances of the x/y/z-elements to assess coupling between them. Additionally, we measured and calculated the coupling between z-elements in the array configuration. Finally, we performed electric field simulations to evaluate the stimulation intensity and focality of the coil and compared the results to conventional TMS coils as well as demonstrated suitability of the 3-axis coil for a multichannel array configuration. RESULTS: The experimentally obtained dB/dt values validated the computational model of the 3-axis coil and therefore confirmed that both the coil and stimulator system are operating as intended. The air-cooling system was effective for brief high-frequency pulse trains and extended single- and paired-pulse TMS protocols. The electromagnetic simulations suggested that an array of the 3-axis coils would have comparable stimulation intensity to conventional TMS coils, therefore enabling clearly suprathreshold stimulation of the human brain. The recorded coil coupling between the x/y/z-elements was < 1% and the maximal coupling between z-elements in the array configuration was 1.8% and 3.4% for the measured and calculated values, respectively. CONCLUSION: We presented a 3-axis coil intended for multichannel TMS arrays. The electromagnetic measurements and simulations verified that the coil fabrication met the desired specifications and that the inductive coupling between the elements was negligible. The air-cooled 3-axis TMS coil appears suitable to be used as an element in multichannel TMS arrays.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Encéfalo / Campos Eletromagnéticos / Estimulação Magnética Transcraniana Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Encéfalo / Campos Eletromagnéticos / Estimulação Magnética Transcraniana Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article