Endobronchial Navigation Guided by Cone-Beam CT-Based Augmented Fluoroscopy without a Bronchoscope: Feasibility Study in Phantom and Swine.
de Ruiter, Quirina M B; Karanian, John W; Bakhutashvili, Ivane; Esparza-Trujillo, Juan A; Varble, Nicole A; van der Sterren, William; Schampaert, Stephanie; van der Bom, Imramsjah M J; Li, Xiaobai; Mauda-Havakuk, Michal; Fontana, Joseph R; Pritchard, William F; Wood, Bradford J.
Afiliação
  • de Ruiter QMB; Center for Interventional Oncology, Radiology & Imaging Sciences, National Institutes of Health Clinical Center, MSC 1182, Bldg. 10, Room 1C341, Bethesda, MD, 20892. Electronic address: bwood@nih.gov.
  • Karanian JW; Center for Interventional Oncology, Radiology & Imaging Sciences, National Institutes of Health Clinical Center, MSC 1182, Bldg. 10, Room 1C341, Bethesda, MD, 20892.
  • Bakhutashvili I; Center for Interventional Oncology, Radiology & Imaging Sciences, National Institutes of Health Clinical Center, MSC 1182, Bldg. 10, Room 1C341, Bethesda, MD, 20892.
  • Esparza-Trujillo JA; Center for Interventional Oncology, Radiology & Imaging Sciences, National Institutes of Health Clinical Center, MSC 1182, Bldg. 10, Room 1C341, Bethesda, MD, 20892.
  • Varble NA; Philips, Best, The Netherlands.
  • van der Sterren W; Philips, Best, The Netherlands.
  • Schampaert S; Philips, Best, The Netherlands.
  • van der Bom IMJ; Philips, Best, The Netherlands.
  • Li X; Biostatistics and Clinical Epidemiology Services, Office of the Director, National Institutes of Health Clinical Center, Bethesda, Maryland.
  • Mauda-Havakuk M; Center for Interventional Oncology, Radiology & Imaging Sciences, National Institutes of Health Clinical Center, MSC 1182, Bldg. 10, Room 1C341, Bethesda, MD, 20892.
  • Fontana JR; Pulmonary and Vascular Medicine Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland.
  • Pritchard WF; Center for Interventional Oncology, Radiology & Imaging Sciences, National Institutes of Health Clinical Center, MSC 1182, Bldg. 10, Room 1C341, Bethesda, MD, 20892.
  • Wood BJ; Center for Interventional Oncology, Radiology & Imaging Sciences, National Institutes of Health Clinical Center, MSC 1182, Bldg. 10, Room 1C341, Bethesda, MD, 20892.
J Vasc Interv Radiol ; 31(12): 2122-2131, 2020 Dec.
Article em En | MEDLINE | ID: mdl-33012647
ABSTRACT

PURPOSE:

To evaluate the accuracy of cone-beam computed tomography (CT)-based augmented fluoroscopy (AF) image guidance for endobronchial navigation to peripheral lung targets.

METHODS:

Prototypic endobronchial navigation AF software that superimposed segmented airways, targets, and pathways based on cone-beam CT onto fluoroscopy images was evaluated ex vivo in fixed swine lungs and in vivo in healthy swine (n = 4) without a bronchoscope. Ex vivo and in vivo (n = 3) phase 1 experiments used guide catheters and AF software version 1, whereas in vivo phase 2 (n = 1) experiments also used an endovascular steerable guiding sheath, upgraded AF software version 2, and lung-specific low-radiation-dose protocols. First-pass navigation success was defined as catheter delivery into a targeted airway segment solely using AF, with second-pass success defined as reaching the targeted segment by using updated AF image guidance based on confirmatory cone-beam CT. Secondary outcomes were navigation error, navigation time, radiation exposure, and preliminary safety.

RESULTS:

First-pass success was 100% (10/10) ex vivo and 19/24 (79%) and 11/15 (73%) for in vivo phases 1 and 2, respectively. Phase 2 second-pass success was 4/4 (100%). Navigation errors were 2.2 ± 1.2 mm ex vivo and 4.9 ± 3.2 mm and 4.0 ± 2.6 mm for in vivo phases 1 and 2, respectively. No major device-related complications were observed in the in vivo experiments.

CONCLUSIONS:

Endobronchial navigation is feasible and accurate with cone-beam CT-based AF image guidance. AF can guide endobronchial navigation with endovascular catheters and steerable guiding sheaths to peripheral lung targets, potentially overcoming limitations associated with bronchoscopy.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Cateterismo / Radiografia Intervencionista / Imagens de Fantasmas / Tomografia Computadorizada de Feixe Cônico / Catéteres / Pulmão Limite: Animals Idioma: En Revista: J Vasc Interv Radiol Assunto da revista: ANGIOLOGIA / RADIOLOGIA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Cateterismo / Radiografia Intervencionista / Imagens de Fantasmas / Tomografia Computadorizada de Feixe Cônico / Catéteres / Pulmão Limite: Animals Idioma: En Revista: J Vasc Interv Radiol Assunto da revista: ANGIOLOGIA / RADIOLOGIA Ano de publicação: 2020 Tipo de documento: Article