Your browser doesn't support javascript.
loading
Radiological evaluation of a new straight electrode array compared to its precursors.
Ketterer, Manuel Christoph; Aschendorff, A; Arndt, S; Speck, I; Rauch, A K; Beck, R; Hassepass, F.
Afiliação
  • Ketterer MC; Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany. manuel.christoph.ketterer@uniklinik-freiburg.de.
  • Aschendorff A; Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Arndt S; Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Speck I; Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Rauch AK; Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Beck R; Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
  • Hassepass F; Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
Eur Arch Otorhinolaryngol ; 278(10): 3707-3714, 2021 Oct.
Article em En | MEDLINE | ID: mdl-33090276
ABSTRACT

OBJECTIVE:

The aim of this study is to examine electrode array coverage, scalar position and dislocation rate in straight electrode arrays with special focus on a new electrode array with 26 mm in lengths. STUDY

DESIGN:

Retrospective study.

SETTING:

Tertiary academic center. PATIENTS 201 ears implanted between 2013 and 2019. MAIN OUTCOME

MEASURES:

We conducted a comparative analysis of patients implanted with lateral wall electrode arrays of different lengths (F24 = MED-EL Flex24, F26 = MED-EL Flex26, F28 = MED-EL Flex28 and F31.5 = MED-EL FlexSoft). Cone beam computed tomography was used to determine electrode array position (scala tympani (ST) versus scala vestibuli (SV), intracochlear dislocation, position of dislocation and insertion angle).

RESULTS:

Study groups show no significant differences regarding cochlear size which excludes influences by cochlear morphology. As expected, the F24 showed significant shorter insertion angles compared to the longer electrode arrays. The F26 electrode array showed no signs of dislocation or SV insertion. The electrode array with the highest rate of ST dislocations was the F31.5 (26.3%). The electrode array with the highest rates of SV insertions was the F28 (5.75%). Most of the included electrode arrays dislocate between 320° and 360° (mean 346.4°; range from 166° to 502°).

CONCLUSION:

The shorter F24 and the new straight electrode array F26 show less or no signs of scalar dislocation, neither for round window nor for cochleostomy insertion than the longer F28 and the F31.5 array. As expected, the cochlear coverage is increasing with length of the electrode array itself but with growing risk for scalar dislocation and with the highest rates of dislocation for the longest electrode array F31.5. Position of intracochlear dislocation is in the apical cochlear part in the included lateral wall electrode arrays.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Implantes Cocleares / Implante Coclear Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Eur Arch Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Implantes Cocleares / Implante Coclear Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Eur Arch Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha