Validation of the BD FACSPresto system for the measurement of CD4 T-lymphocytes and hemoglobin concentration in HIV-negative and HIV-positive subjects.
Lu, Xiaofan; Sun, Hanxiao; Li, Haicong; Xia, Wei; Wu, Hao; Chen, Daihong; Tan, Meiyu; Yu, Shijun; Zhang, Tong; Sheng, Huiming; Zhu, Zhaoqin.
Afiliação
  • Lu X; Center for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China.
  • Sun H; Beijing Key Laboratory for HIV/AIDS Research, Beijing, China.
  • Li H; Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Xia W; Shanghai Public Health Clinical Center, Fudan University, Shanghai, China.
  • Wu H; Center for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China.
  • Chen D; Center for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China.
  • Tan M; Beijing Key Laboratory for HIV/AIDS Research, Beijing, China.
  • Yu S; Shanghai Public Health Clinical Center, Fudan University, Shanghai, China.
  • Zhang T; Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Sheng H; BD Biosciences, 2350 Qume Drive, San Jose, CA, 95131, USA.
  • Zhu Z; Center for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China. zt_doc@ccmu.edu.cn.
Sci Rep ; 10(1): 19605, 2020 11 11.
Article em En | MEDLINE | ID: mdl-33177659
This study aimed to compare the performance of the BD FACSPresto system with the conventional standard-of-care technologies for the measurement of absolute CD4 count (AbsCD4), CD4 percentage (CD4%) and total hemoglobin concentration (Hb) in capillary and venous blood samples of HIV-negative and HIV-positive subjects. A total of 1304 participants were included in this prospective cohort study. Both venous and capillary blood samples were analyzed using the BD FACSPresto system and the results were compared against the BD FACSCalibur for enumerating AbsCD4 and CD4% and Sysmex XT-4000i hematology analyzer for determining Hb levels. Method comparison studies were performed using Deming regression and Bland-Altman plots. The Deming regression analyses comparing the accuracy of the BD FACSPresto system with the reference standard technologies demonstrated a significant linear correlation between the AbsCD4, CD4%, and Hb values generated by the two platforms. The 95% CI of the slopes for AbsCD4, CD4%, and Hb levels were 0.94-0.99, 0.99-1.01 and 0.86-0.93, respectively (P < 0.001). Bland-Altman plots for AbsCD4, CD4%, and Hb levels demonstrated close agreement between the BD FACSPresto system and the reference standards for all study participants. The performance and accuracy of BD FACSPresto system was comparable to the reference standard technologies. The BD FACSPresto system can be used interchangeably with BD FACSCalibur platform for CD4 and Sysmex XT-4000i hematology analyzer for Hb concentrations in resource-limited settings thus, improving accessibility to point-of-care testing services.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Hemoglobinas / Infecções por HIV / Contagem de Linfócito CD4 / Citometria de Fluxo Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Female / Humans / Male / Pregnancy Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Hemoglobinas / Infecções por HIV / Contagem de Linfócito CD4 / Citometria de Fluxo Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Female / Humans / Male / Pregnancy Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China